A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults
- 8 July 2015
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (10) , 2069-2071
Abstract
In younger adults with fractures of the femoral neck, anatomic reduction is compulsory and maintaining the reduction is crucial. Both cannulated screws and dynamic hip screw (DHS) have the capacity of compression in the fracture site but the strength for keeping reduction is not the same. The aim of this study was to compare the results with fixations of the femoral neck fractures with cannulated screws versus dynamic hip screw. This is a randomized clinical trial study on 58 cases with a minimum of one year follow-up. Leg length discrepancy, Harris Hip Score, infection, avascular necrosis of femoral head, and union of the fracture site were evaluated. There were two failures in the first trimester in the cannulated screw group and three more failures in the second and third trimesters in this group. In the DHS group, there was no reduction and fixation failure in the follow-up period. There was no fixation failure (0 %) in Group B (DHS) but there were five fixation failures (18 %) in Group A (screw), and there is significant difference between the groups (p < 0.001). The rate of avascular necrosis was the same in both groups. It seems to us that in our practice the fixation of femoral neck fracture in young adults with the DHS is a better option compared with the osteosynthsis with multiple cannulated screws.Keywords
This publication has 23 references indexed in Scilit:
- Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femurInternational Orthopaedics, 2013
- Radiographic quantification of dynamic hip screw migrationInternational Orthopaedics, 2013
- Ensaio estático de flexão no parafuso deslizante do quadril AF (DHS- AF®)Acta Ortopedica Brasileira, 2013
- A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip ScrewJournal of Trauma: Injury, Infection & Critical Care, 2011
- Quantification of cancellous bone-compaction due to DHS® Blade insertion and influence upon cut-out resistanceClinical Biomechanics, 2009
- Delayed union of an operated fracture of the femoral neckJournal of Orthopaedics and Traumatology, 2008
- Locked Plating: Biomechanics and BiologyTechniques in Orthopaedics, 2007
- Delayed internal fixation of fractures of the neck of the femur in young adultsThe Journal of Bone and Joint Surgery. British volume, 2004
- Relationship of Mechanical Factors to the Strength of Proximal Femur Fractures Fixed with Cancellous ScrewsJournal of Orthopaedic Trauma, 1996
- Complications of Femoral Neck Fracture in Young Adults1986