Inter-comparison of two cavity ring-down spectroscopy analyzers for atmospheric 13CO2 / 12CO2 measurement
Preprint
- 25 April 2016
- preprint
- Published by Copernicus GmbH in EGUsphere
- Vol. 2016, 1-30
Abstract
The isotope ratio infrared spectroscopy (IRIS) permits in situ and continuous measurements of CO2 isotopic composition under ambient conditions. Previous studies mainly focused on single IRIS instrument performance, few studies have paid attention to the comparability among different IRIS instruments. In this study, we carried out laboratory and ambient measurements of two Picarro CO2 δ13C analyzers (G1101-i and G2201-i), and evaluated their performance and comparability. The best precision were 0.08 ~ 0.15 ‰ and 0.01 ~ 0.04 ‰, the dependence of δ13C on CO2 concentration were 0.46 ‰ per 100 ppm and 0.09 ‰ per 100 ppm, the instrument drift ranged from 0.92 ~ 1.09 ‰ and 0.19 ~ 0.37 ‰. After upgradation of G1101-i, the sensitivity of δ13C on water vapor mixing ratio were 0.15 ‰ / % H2O and 0.13 ‰ / % H2O for the G1101-i and G2201-i, respectively. The accuracy after corrected by the two-point mixing ratio gain and offset calibration method ranged from −0.04 ~ 0.09 ‰ and −0.13 ~ 0.03 ‰ for G1101-i and G2201-i, respectively. Atmospheric δ13C measurements captured the rapidly changing atmospheric δ13C signals, with the difference of 0.07 ± 0.24 ‰ and 0.05 ± 0.30 ‰ between G1101-i upgraded before and after and G2201-i. Before upgradation of G1101-i, a significant linear correlation was observed between the δ13C difference and water vapor concentration, but there is no significant correlation after upgradation of G1101-i. The difference of Keeling intercept values between G1101-i and G2201-i decrease from 1.24 ‰ to 0.36 ‰, which indicate the importance of consistency among different IRIS instruments.Keywords
All Related Versions
- Published version: Atmospheric Measurement Techniques, 9 (8), 3879.
Funding Information
- National Natural Science Foundation of China (41571130043, 31290221 and 31470500)
This publication has 29 references indexed in Scilit:
- Mixing ratio and carbon isotopic composition investigation of atmospheric CO 2 in Beijing, ChinaScience of The Total Environment, 2016
- Using a laser-based CO2 carbon isotope analyser to investigate gas transfer in geological mediaApplied Physics B, 2012
- Eddy covariance measurements of CO2 isotopologues with a quantum cascade laser absorption spectrometerAgricultural and Forest Meteorology, 2012
- Continuous measurement of water vapor D/H and 18O/16O isotope ratios in the atmosphereJournal of Hydrology, 2008
- Quantum cascade laser based spectrometer for in situ stable carbon dioxide isotope measurementsInfrared Physics & Technology, 2008
- High-precision δ13CO2 analysis by FTIR spectroscopy using a novel calibration strategyJournal of Molecular Structure, 2006
- Measuring field-scale isotopic CO2 fluxes with tunable diode laser absorption spectroscopy and micrometeorological techniquesAgricultural and Forest Meteorology, 2004
- Tunable diode laser absorption spectroscopy for stable isotope studies of ecosystem–atmosphere CO2 exchangeAgricultural and Forest Meteorology, 2003
- The use of stable isotopes to study ecosystem gas exchangeOecologia, 2000
- The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS)Applied Physics B, 1993