Caveat Emptor: The Role of Suboptimal Bronchoscope Repair Practices by a Third-Party Vendor in a Pseudo-Outbreak ofPseudomonasin Bronchoalveolar Lavage Specimens
Authors:
- Sara E. CosgroveSCSara E. Cosgrove
- Polly RistainoPRPolly Ristaino
- Anne Caston-GaaACAnne Caston-Gaa
- Donna P. FellermanDFDonna P. Fellerman
- Elaine F. NowakowskiENElaine F. Nowakowski
- Karen C. CarrollKCKaren C. Carroll
- 1 March 2012
- journal article
- editorial
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 33 (3) , 224-229
Abstract
Objective.: To describe a pseudo-outbreak associated with loose bronchoscope biopsy ports caused by inadequate bronchoscope repair practices by third-party vendors and to alert healthcare personnel to assess bronchoscope repair practices.Design.: Outbreak investigation.Setting.: A 925-bed tertiary care hospital in Baltimore, Maryland.Patients.: Patients who underwent bronchoscopy with certain bronchoscopes after they had been repaired by a third-party vendor.Methods.: An epidemiologic investigation was conducted to determine the cause ofPseudomonas putidagrowth in 4 bronchoalveolar lavage (BAL) specimens within a 3-day period in May 2008. All bronchoscopes were inspected, and cultures were obtained from bronchoscopes and the environment. Bronchoscope cleaning and maintenance practices were reviewed. Microbiologic results from BAL specimens and medical records were reviewed to find additional cases.Results.: All 4 case patients had undergone bronchoscopy with one of 2 bronchoscopes, both of which had loose biopsy ports. Bronchoscope cultures grewP. putida, Pseudomonas aeruginosa,andStenotrophomonas.TheP. putidastrains from the bronchoscopes matched those from the patients. Specimens from 12 additional patients who underwent bronchoscopy with these bronchoscopes grewP. putida, P. aeruginosa,orStenotrophomonas.No patients developed clinical signs or symptoms of infection, but 7 were treated with antibiotics. Investigation revealed that the implicated bronchoscopes had been sent to an external vendor for repair; examination by the manufacturer revealed irregularities in repairs and nonstandard part replacements.Conclusions.: Third-party vendors without access to proprietary information may contribute to mechanical malfunction of medical devices, which can lead to contamination and incomplete disinfection.Infect Control Hosp Epidemiol2012;33(3):224-229Keywords
This publication has 14 references indexed in Scilit:
- Outbreak of Pseudomonas aeruginosa Infection Associated With Contamination of a Flexible BronchoscopeInfection Control & Hospital Epidemiology, 2009
- Flexible Bronchoscope Damage and Repair Costs in a Bronchoscopy Teaching UnitRespiration, 2008
- CDC/NHSN surveillance definition of health care–associated infection and criteria for specific types of infections in the acute care settingAmerican Journal of Infection Control, 2008
- Pseudomonas aeruginosa and Pseudomonas putida outbreak associated with contaminated water outlets in an oncohaematology paediatric unitJournal of Hospital Infection, 2007
- Pseudomonas putida Septicemia in a Special Care Nursery Due to Contaminated Flush Solutions Prepared in a Hospital PharmacyJournal of Clinical Microbiology, 2005
- Unusual implication of biopsy forceps in outbreaks of Pseudomonas aeruginosa infections and pseudo-infections related to bronchoscopyJournal of Hospital Infection, 2005
- Outbreaks of contaminated broncho-alveolar lavage related to intrinsically defective bronchoscopesJournal of Hospital Infection, 2005
- Pseudo-Outbreak ofPseudomonas aeruginosaandSerratia marcescensRelated to BronchoscopesInfection Control & Hospital Epidemiology, 2003
- An Outbreak ofPseudomonas aeruginosaInfections Associated with Flexible BronchoscopesNew England Journal of Medicine, 2003
- Pseudo-outbreak of Pseudomonas aeruginosa in HIV-infected Patients Undergoing Fiberoptic BronchoscopyScandinavian Journal of Infectious Diseases, 1994