Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
Open Access
- 27 January 2022
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (6) , 1679-1687
Abstract
Point-of-care blood lactate is a promising prognostic biomarker of short-term mortality risk. Portable lactate meters need validation in the prehospital setting before widespread implementation and it is unknown whether the mode of sampling (arterial, capillary or venous) matters. This study aims to compare the StatStrip Xpress Lactate Meter’s (SSX) accuracy to a validated blood gas analyser, ABL90 FLEX (ABL90), in arterial samples in the prehospital environment and to determine if lactate levels measured in venous and capillary blood samples are sufficiently accurate compared to arterial lactate levels. Patients with arterial samples drawn by the prehospital anaesthesiologist for any reason were eligible for inclusion. Simultaneously, three blood samples (arterial, capillary and venous) were analysed on SSX and arterial blood on ABL90. Measurements of agreements were evaluated by Lin’s concordance correlations coefficient (CCC) and Bland–Altman Plots. One-hundred-and-eleven patients were included. SSX showed good accuracy compared to ABL90 in arterial samples with a CCC of 0.92 (95% CI 0.90–0.94). Compared to the arterial samples measured on ABL90, venous samples analysed on SSX showed higher agreement than capillary samples analysed on SSX with CCCs of 0.88 (95% CI 0.85–0.91) and 0.79 (95% CI 0.72–0.85), respectively. Bland–Altman plots showed that SSX lactate measurements in arterial, venous and capillary blood samples all had systematically negative biases compared to ABL90. We conclude that the SSX is accurate in our prehospital setting. Venous samples should be preferred over capillary samples, when arterial samples cannot be obtained.Keywords
This publication has 23 references indexed in Scilit:
- Developing a New Definition and Assessing New Clinical Criteria for Septic ShockJAMA, 2016
- Implementation of the ABL-90 blood gas analyzer in a ground-based mobile emergency care unitScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2015
- Lactate level, aetiology and mortality of adult patients in an emergency department: a cohort studyEmergency Medicine Journal, 2015
- Arterial lactate levels in an emergency department are associated with mortality: a prospective observational cohort studyEmergency Medicine Journal, 2015
- Rationale for using data on biological variationClinical Chemistry and Laboratory Medicine (CCLM), 2015
- The Influence of Blood Lactate Sample Site on Exercise PrescriptionJournal of Strength & Conditioning Research, 2012
- Extending the role of lactate measurement into the prehospital environmentCritical Care, 2009
- The prognostic value of blood lactate levels relative to that of vital signs in the pre-hospital setting: a pilot studyCritical Care, 2008
- Serum Lactate as a Predictor of Mortality in Emergency Department Patients with InfectionAnnals of Emergency Medicine, 2005
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986