Long-Term and Accelerated Life Testing of a Novel Single-Wafer Vacuum Encapsulation for MEMS Resonators

Authors:
  • MHMatthew A. Hopcroft
    Matthew A. Hopcroft
  • BKBongsang Kim
    Bongsang Kim
  • RMRenata Melamud
    Renata Melamud
  • MAManu Agarwal
    Manu Agarwal
  • GYGary Yama
    Gary Yama
  • APAaron Partridge
    Aaron Partridge
  • MLMarkus Lutz
    Markus Lutz
  • TKThomas W. Kenny
    Thomas W. Kenny

Abstract
We have developed a single-wafer vacuum encapsulation for microelectromechanical systems (MEMS), using a thick (20-mum) polysilicon encapsulation to package micromechanical resonators in a pressure 600 cycles of -50 to 80degC, and no measurable change in cavity pressure was seen. We have also performed accelerated leakage tests by driving hydrogen gas in and out of the encapsulation at elevated temperature. Two results have come from these hydrogen diffusion tests. First, hydrogen diffusion rates through the encapsulation at temperatures 300-400degC have been determined. Second, the package was shown to withstand multiple temperature cycles between room and 300-400degC without showing any adverse affects. The high robustness and stability of the encapsulation can be attributed to the clean, high-temperature environment during the sealing process

This publication has 36 references indexed in Scilit: