Fine-Scale Spatial Distribution of Indoor Radon and Identification of Potential Ingress Pathways
Open Access
- 6 August 2025
- journal article
- research article
- Published by MDPI AG in Atmosphere
- Vol. 16 (8) , 943
Abstract
A new generation of compact radon detectors with high sensitivity and fine spatial resolution (1–2 cm scale) was used to investigate indoor radon distribution and identify potential entry pathways. Solid-state nuclear track detectors (Kodak-Pathe LR-115 type II, Dosirad, France), combined with activated carbon fabric (ACC-5092-10), enabled sensitive, spatially resolved radon measurements. Two case studies were conducted: Case 1 involves a room with elevated radon levels suspected to originate from the floor. Case 2 involves a house with persistently high indoor radon concentrations despite active basement ventilation. In the first case, radon emission from the floor was found to be highly inhomogeneous, with concentrations varying by more than a factor of four. In the second, unexpectedly high radon levels were detected at electrical switches and outlets on walls in the living space, suggesting radon transport through wall voids and entry via non-hermetic electrical fittings. These novel detectors facilitate fine-scale mapping of indoor radon concentrations, revealing ingress routes that were previously undetectable. Their use can significantly enhance radon diagnostics and support the development of more effective mitigation strategies.Keywords
Funding Information
- European Union-Next Generation EU (BG-RRP-2.004-0008-C01, KP-06-N58/9)
- Bulgarian National Science Fund (BG-RRP-2.004-0008-C01, KP-06-N58/9)
This publication has 31 references indexed in Scilit:
- The sensitivity of innovative techniques for measuring low levels of radon in the environment using passive detectorsJournal of Environmental Radioactivity, 2024
- Influence of humidity on activated carbon fabrics scheduled for use in high sensitivity radon detectorsApplied Radiation and Isotopes, 2023
- Radon levels and indoor air quality after application of thermal retrofit measures—a case studyAir Quality, Atmosphere & Health, 2022
- Radon interventions around the globe: A systematic reviewHeliyon, 2019
- Laboratory facility to create reference radon + thoron atmosphere under dynamic exposure conditionsJournal of Environmental Radioactivity, 2017
- Energy-efficient reconstructions and indoor radon: the impact assessed by CDs/DVDsJournal of Environmental Radioactivity, 2015
- Testing radon mitigation techniques in a pilot house from Băiţa-Ştei radon prone area (Romania)Journal of Environmental Radioactivity, 2015
- Temperature calibration formula for activated charcoal radon collectorsJournal of Environmental Radioactivity, 2011
- Water adsorption with hysteresis effect onto microporous activated carbon fabricsAdsorption, 2007
- A new technique for radon measurement based on a combination of a track-etch detector and activated charcoalInternational Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1991