Nucleus Replacement With the DASCOR Disc Arthroplasty Device
Authors:
- Michael AhrensMAMichael Ahrens
- Anthony TsantrizosATAnthony Tsantrizos
- Peter DonkerslootPDPeter Donkersloot
- Frederic MartensFMFrederic Martens
- Philippe LauwerynsPLPhilippe Lauweryns
- Jean Charles Le HuecJHJean Charles Le Huec
- Slawomir MoszkoSMSlawomir Moszko
- Zsolt FeketeZFZsolt Fekete
- John ShermanJSJohn Sherman
- Hansen A. YuanHYHansen A. Yuan
- Henry HalmHHHenry Halm
- 1 June 2009
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (13) , 1376-1384
Abstract
A prospective, nonrandomized multicenter study of lumbar disc nucleus replacement using the DASCOR Disc Arthroplasty Device. An interim analysis of clinical results is presented, obtained from European patients enrolled in 2 studies. To determine the safety and efficacy of the DASCOR Device for the treatment of symptomatic single-level degenerative disc disease (DDD). Patients suffering from DDD have been limited to a choice between nonoperative therapies or invasive surgical treatments such as total disc replacement or spinal fusion. The DASCOR Device was developed to provide an alternative treatment with a less invasive surgical intervention. A total of 85 patients from 11 European centers were enrolled in 1 of 2 studies between February 2003 and July 31, 2007. Data were collected before surgery and after surgery at 6 weeks and at 3, 6, 12, and 24 months. The clinical outcome measures were obtained from the Visual Analog Scale (VAS) for back pain, the Oswestry Disability Index (ODI), radiographic assessments, and records of analgesic medication use. Mean VAS and ODI scores improved significantly after 6 weeks and throughout the 2 years. Radiographic results demonstrated, at a minimum, maintenance of disc height with no device expulsion and, despite Modic-Type 1 changes, no subsidence. Fourteen patients had serious adverse events including device explants in 7 patients (7 of 85), in which the main complication was resumed back pain after time. Patients’ rate of analgesic medication decreased dramatically over time, with all patients experiencing significant improvements after 3 months and nearly no analgesic medication or narcotic drug use at 2 years. The interim outcomes showed significant improvements in mean ODI and VAS scores. The results of these European studies suggest that the DASCOR Device may be a safe and effective less-invasive surgical option for patients with DDD.Keywords
This publication has 8 references indexed in Scilit:
- Mechanical and Biomechanical Characterization of a Polyurethane Nucleus Replacement Device Injected and Cured In Situ Within a BalloonInternational Journal of Spine Surgery, 2008
- Lokale Wirbelkörperdestruktion nach Migration eines NukleusersatzimplantatesZeitschrift für Orthopädie und Unfallchirurgie, 2007
- Spine arthroplasty: a historical reviewEuropean Spine Journal, 2002
- Artificial Nucleus ReplacementSpine, 2002
- New Technologies in SpineSpine, 2002
- Prosthetic Disc Replacement: The Future?Clinical Orthopaedics and Related Research, 2002
- Quantification of Lumbar Intradiscal Deformation During Flexion and Extension, by Mathematical Analysis of Magnetic Resonance Imaging Pixel Intensity ProfilesSpine, 1997
- Migration of the Nucleus Pulposus Within the Intervertebral Disc During Flexion and Extension of the SpineSpine, 1996