Abstract
I have three concerns about the description of central venous catheterization in the video by Graham et al. (May 24 issue).1 First, it is misleading to describe the risk of hemothorax as “not applicable” when the internal jugular approach is used, since hemothorax is a known complication.2 Second, head rotation of 45 degrees increases the overlap of the carotid artery by the internal jugular vein,3 increasing the risk of arterial puncture.4 For this reason, most authors recommend a near-midline position of the head. Third, the manometer technique that is shown is inadequate. Blood rising more than 30 cm in the vertical tube indicates arterial catheterization; however, the absence of this increase does not exclude the possibility of arterial puncture if the needle tip abuts the artery wall. Arterial puncture can be excluded only by filling the horizontal catheter with more than 30 cm of blood and then holding it upright and observing a fall in the column. Finally, in light of the potential for serious or fatal complications, it is difficult to justify an attempt at central venous catheterization without an experienced operator present.

This publication has 12 references indexed in Scilit: