Central Venous Catheterization
- 30 August 2007
- journal article
- letter
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 357 (9) , 943-945
Abstract
I have three concerns about the description of central venous catheterization in the video by Graham et al. (May 24 issue).1 First, it is misleading to describe the risk of hemothorax as “not applicable” when the internal jugular approach is used, since hemothorax is a known complication.2 Second, head rotation of 45 degrees increases the overlap of the carotid artery by the internal jugular vein,3 increasing the risk of arterial puncture.4 For this reason, most authors recommend a near-midline position of the head. Third, the manometer technique that is shown is inadequate. Blood rising more than 30 cm in the vertical tube indicates arterial catheterization; however, the absence of this increase does not exclude the possibility of arterial puncture if the needle tip abuts the artery wall. Arterial puncture can be excluded only by filling the horizontal catheter with more than 30 cm of blood and then holding it upright and observing a fall in the column. Finally, in light of the potential for serious or fatal complications, it is difficult to justify an attempt at central venous catheterization without an experienced operator present.Keywords
This publication has 12 references indexed in Scilit:
- Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patientsCritical Care, 2006
- Effect of head rotation on vascular anatomy of the neck: An ultrasound studyThe Journal of Emergency Medicine, 2006
- Risk factors for hospital-acquired methicillin-resistant Staphylococcus aureus bacteraemia: a case-control studyEpidemiology and Infection, 2006
- Mechanical Complications of Central Venous CathetersJournal of Intensive Care Medicine, 2006
- Anchoring of the internal jugular vein with a pilot needle to facilitate its puncture with a wide bore needle: a randomised, prospective, clinical studyAnaesthesia, 2005
- Broken guide wire - a fault of design?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Preventing Complications of Central Venous CatheterizationNew England Journal of Medicine, 2003
- Device-related sources of bacteraemia in English hospitals—opportunities for the prevention of hospital-acquired bacteraemiaJournal of Hospital Infection, 2003
- The Internal Jugular Vein Maintains its Regional Anatomy and Patency After Carotid Endarterectomy: A Prospective StudyAnnals of Surgery, 2001
- Head Rotation During Internal Jugular Vein Cannulation and the Risk of Carotid Artery PunctureAnesthesia & Analgesia, 1996