An EMG-Driven Musculoskeletal Model for Estimating Continuous Wrist Motion
- 1 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (12) , 3113-3120
Abstract
EMG-based continuous wrist joint motion estimation has been identified as a promising technique with huge potential in assistive robots. Conventional data-driven model-free methods tend to establish the relationship between the EMG signal and wrist motion using machine learning or deep learning techniques, but cannot interpret the functional relationship between neuro-commands and relevant joint motion. In this paper, an EMG-driven musculoskeletal model is proposed to estimate continuous wrist joint motion. This model interprets the muscle activation levels from EMG signals. A muscle-tendon model is developed to compute the muscle force during the voluntary flexion/extension movement, and a joint kinematic model is established to estimate the continuous wrist motion. To optimize the subject-specific physiological parameters, a genetic algorithm is designed to minimize the differences of joint motion prediction from the musculoskeletal model and joint motion measurement using motion data during training. Results show that mean root-mean-square-errors are 10.08°, 10.33°, 13.22° and 17.59° for single flexion/extension, continuous cycle and random motion trials, respectively. The mean coefficient of determination is over 0.9 for all the motion trials. The proposed EMG-driven model provides an accurate tracking performance based on user’s intention.Keywords
Funding Information
- Engineering and Physical Sciences Research Council of U.K. (EP/S019219/1)
This publication has 29 references indexed in Scilit:
- Sensitivity of subject-specific models to Hill muscle–tendon model parameters in simulations of gaitJournal of Biomechanics, 2016
- Corrections to “Neural Data-Driven Musculoskeletal Modeling for Personalized Neurorehabilitation Technologies” [May 16 879-893]IEEE Transactions on Biomedical Engineering, 2016
- Design and control of a robotic wrist orthosis for joint rehabilitation2015
- A State-Space EMG Model for the Estimation of Continuous Joint MovementsIEEE Transactions on Industrial Electronics, 2015
- Benchmarking of dynamic simulation predictions in two software platforms using an upper limb musculoskeletal modelComputer Methods in Biomechanics and Biomedical Engineering, 2014
- Dynamic analysis of the upper limb during activities of daily living: Comparison of methodologiesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2013
- Estimation of musculotendon kinematics in large musculoskeletal models using multidimensional B-splinesJournal of Biomechanics, 2012
- Muscle moment arm and normalized moment contributions as reference data for musculoskeletal elbow and wrist joint modelsJournal of Biomechanics, 2009
- Sensitivity of a Hill-based muscle model to perturbations in model parametersJournal of Biomechanics, 2006