Microfluidic High-Resolution Free-Flow Isoelectric Focusing
- 29 September 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (21) , 8190-8198
Abstract
A microfluidic free-flow isoelectric focusing glass chip for separation of proteins is described. Free-flow isoelectric focusing is demonstrated with a set of fluorescent standards covering a wide range of isoelectric points from pH 3 to 10 as well as the protein HSA. With respect to an earlier developed device, an improved microfluidic FFE chip was developed. The improvements included the usage of multiple sheath flows and the introduction of preseparated ampholytes. Preseparated ampholytes are commonly used in large-scale conventional free-flow isoelectric focusing instruments but have not been used in micromachined devices yet. Furthermore, the channel depth was further decreased. These adaptations led to a higher separation resolution and peak capacity, which were not achieved with previously published free-flow isoelectric focusing chips. An almost linear pH gradient ranging from pH 2.5 to 11.5 between 1.2 and 2 mm wide was generated. Seven isoelectric focusing markers were successfully and clearly separated within a residence time of 2.5 s and an electrical field of 20 V mm-1. Experiments with pI markers proved that the device is fully capable of separating analytes with a minimum difference in isoelectric point of Δ(pI) = 0.4. Furthermore, the results indicate that even a better resolution can be achieved. The theoretical minimum difference in isoelectric point is Δ(pI) = 0.23 resulting in a peak capacity of 29 peaks within 1.8 mm. This is an 8-fold increase in peak capacity to previously published results. The focusing of pI markers led to an increase in concentration by factor 20 and higher. Further improvement in terms of resolution seems possible, for which we envisage that the influence of electroosmotic flow has to be further reduced. The performance of the microfluidic free-flow isoelectric focusing device will enable new applications, as this device might be used in clinical analysis where often low sample volumes are available and fast separation times are essential.Keywords
This publication has 21 references indexed in Scilit:
- Microchip free‐flow electrophoresis on glass substrate using laser‐printing toner as structural materialElectrophoresis, 2006
- Micro freef‐low IEF enhanced by active cooling and functionalized gelsElectrophoresis, 2006
- Electrostatic induction of the electric field into free-flow electrophoresis devicesLab on a Chip, 2006
- Isotachophoresis in Free-Flow Using a Miniaturized DeviceAnalytical Chemistry, 2006
- Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranesLab on a Chip, 2006
- Free-Flow Electrophoresis on an Anodic Bonded Glass MicrochipAnalytical Chemistry, 2005
- Determination of picomolar concentrations of proteins using novel amino reactive chameleon labels and capillary electrophoresis laser-induced fluorescence detectionElectrophoresis, 2005
- A free-flow electrophoresis chip device for interfacing capillary isoelectric focusing on-line with electrospray mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Continuous flow isoelectric focusing for purification of proteinsElectrophoresis, 1998
- Continuous Separation of High Molecular Weight Compounds Using a Microliter Volume Free-Flow Electrophoresis MicrostructureAnalytical Chemistry, 1996