Abstract
Although advances in the field of cardiovascular surgery have improved outcomes for patients with acute DeBakey type I aortic dissection, postoperative in-hospital mortality and morbidity remain substantial. The frozen elephant trunk technique has become a treatment option for this disease and was developed primarily to extend repair into the proximal descending thoracic aorta during aortic arch repair (because the descending thoracic aorta is largely inaccessible via median sternotomy), thus avoiding, delaying, or facilitating subsequent repair of residual native aorta. In this review, we discuss the evidence for and future development of frozen elephant trunk reconstruction for acute DeBakey type I aortic dissection.Keywords
This publication has 37 references indexed in Scilit:
- Acute type I aortic dissection: Traditional versus hybrid repair with antegrade stent delivery to the descending thoracic aortaThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Total aortic arch replacement with the frozen elephant trunk technique: 10-year follow-up single-centre experience†European Journal of Cardio-Thoracic Surgery, 2013
- Long-Term Outcome of Aortic Dissection With Patent False LumenCirculation, 2012
- Long-Term Results After Repair of Type A Acute Aortic Dissection According to False Lumen PatencyThe Annals of Thoracic Surgery, 2009
- Arch Aneurysm Repair With Long Elephant Trunk: A 10-Year Experience in 111 PatientsThe Annals of Thoracic Surgery, 2009
- Treatment of complex disease of the thoracic aorta: the frozen elephant trunk technique with the E-vita open prosthesis☆European Journal of Cardio-Thoracic Surgery, 2009
- Staged repair of thoracic and thoracoabdominal aortic aneurysms using the elephant trunk technique: a consecutive series of 215 first stage and 120 complete repairs☆European Journal of Cardio-Thoracic Surgery, 2008
- Patency of distal false lumen in acute dissection: extent of resection and prognosisInteractive CardioVascular and Thoracic Surgery, 2006
- The Elephant Trunk Technique for Staged Repair of Complex Aneurysms of the Entire Thoracic AortaThe Annals of Thoracic Surgery, 2006
- Extensive Aortic Replacement using “Elephant Trunk” ProsthesisThe Thoracic and Cardiovascular Surgeon, 1983