Long-term Evaluation of Corneal Biomechanical Properties After Corneal Cross-linking for Keratoconus: A 4-Year Longitudinal Study
Authors:
- Mohammad-Reza SedaghatMSMohammad-Reza Sedaghat
- Hamed Momeni-MoghaddamHMHamed Momeni-Moghaddam
- Renato AmbrósioRARenato Ambrósio
- Cynthia J. RobertsCRCynthia J. Roberts
- Abbas-Ali YektaAYAbbas-Ali Yekta
- Zeynab DaneshZDZeynab Danesh
- Sven ReisdorfSRSven Reisdorf
- Mehdi KhabazkhoobMKMehdi Khabazkhoob
- Hamid-Reza HeidariHHHamid-Reza Heidari
- Javad SadeghiJSJavad Sadeghi
- 1 December 2018
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 34 (12) , 849-856
Abstract
PURPOSE: To compare the long-term changes in corneal biomechanics, topography, and tomography before and 4 years after corneal cross-linking (CXL) with the Dresden protocol and correlate these changes with visual acuity. METHODS: In this longitudinal study, 18 eyes of 18 patients with progressive keratoconus who were treated with CXL were included. All patients received a standard ophthalmological examination and were examined by Placido disc–based topography, Scheimpflug tomography, and biomechanical assessments with the Corvis ST (OCULUS Optikgeräte GmbH, Wetzlar, Germany) and Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) before and 4 years after CXL. The main outcome measures were dynamic corneal response (DCR) parameters obtained from the Corvis ST, corneal hysteresis (CH), corneal resistance factor (CRF), visual acuity, refraction, corneal curvature, and corneal thickness. RESULTS: There were no significant differences in mean visual acuity, refraction, intraocular pressure, corneal topography, corneal astigmatism in both corneal surfaces, maximum keratometry, corneal thickness at apical and thinnest points, thickness profile indices, corneal volume, and specular microscopy before and 4 years after CXL ( P > .05). Significant changes were observed in many DCR parameters, including radius at highest concavity and integrated inverse radius, both of which were consistent with stiffening. The CH and CRF values after CXL were not statistically significant. The new parameters using the Corvis ST include integrated inverse concave radius, which showed a significant decrease 1.07 ± 0.93 mm −1 , consistent with stiffening. The corneal stiffness parameter at the first applanation, Ambrósio's Relational Thickness to the horizontal profile, deformation amplitude ratio, and Corvis Biomechanical Index as a combined biomechanical screening parameter did not show significant changes. CONCLUSIONS: CXL is a minimally invasive treatment option to prevent keratoconus progression over 4 years. Pressure-derived biomechanical parameters obtained from the ORA did not show any change following CXL at 4 years of follow-up, whereas the Corvis ST DCR parameters detected changes in corneal biomechanical properties. [ J Refract Surg . 2018;34(12):849–856.]Keywords
This publication has 48 references indexed in Scilit:
- Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important?Eye and Vision, 2016
- Collagen cross-linking treatment effects on corneal dynamic biomechanical propertiesExperimental Eye Research, 2015
- Global Consensus on Keratoconus and Ectatic DiseasesCornea, 2015
- Biomechanical properties of the keratoconic cornea: a reviewClinical and Experimental Optometry, 2015
- Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin MicroscopyInvestigative Ophthalmology & Visual Science, 2014
- Biomechanical Changes After Repeated Collagen Cross-Linking on Human Corneas Assessed In Vitro Using Scanning Acoustic MicroscopyInvestigative Ophthalmology & Visual Science, 2014
- Biomechanical Properties of Human Corneas Following Low- and High-Intensity Collagen Cross-Linking Determined With Scanning Acoustic MicroscopyInvestigative Ophthalmology & Visual Science, 2013
- The Effect of Riboflavin/UVA Collagen Cross-linking Therapy on the Structure and Hydrodynamic Behaviour of the Ungulate and Rabbit Corneal StromaPLOS ONE, 2013
- Interlamellar cohesion after corneal crosslinking using riboflavin and ultraviolet A lightBritish Journal of Ophthalmology, 2011
- Keratoconus evaluation using the Orbscan Topography SystemJournal of Cataract & Refractive Surgery, 2000