Variable Utilization-Level Scheme for Load-Sharing Control of Wind Farm
- 24 October 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 856-868
Abstract
Under Maximum Power Point Tracking (MPPT) control, wind power is not dispatchable and can be highly disturbing to the supply-demand balance control in particularly context of microgrid. To effective dispatch wind power according to e.g. operator command or market schedule, a variable utilization level (UL) scheme is proposed for a wind power plant (WPP) to fulfill the dispatch order while reducing the loss of total energy production. Considering different wind conditions, the proposed scheme directs the power output for each wind turbine (WT) according to a specific utilization level (UL), which is adaptively adjusted according to WT rotor speed so that less reduction of energy production can be ensured. Meanwhile, more rotational kinetic energy (KE) stored can be stored in WPP, which can be later released for system support when needed. The proposed variable UL scheme is fully investigated in a doubly fed induction generator (DFIG)-based WPP and the results clearly indicate the proposed scheme can harvest more energy than the conventional same UL one while fulfilling the dispatch demand.Keywords
Funding Information
- Hong Kong RGC Theme Based Research Scheme (T23-701/14N)
- National Natural Science Foundation of China (51707172, 71331001, 91547113)
- Science and Technology Projects of Hunan Province (2017WK2050)
- Zhejiang Provincial Natural Science Foundation of China (LY15E070001)
This publication has 22 references indexed in Scilit:
- Coordinated Control Strategies for Offshore Wind Farm Integration via VSC-HVDC for System Frequency SupportIEEE Transactions on Energy Conversion, 2017
- Advanced Control Strategies of PMSG-Based Wind Turbines for System Inertia SupportIEEE Transactions on Power Systems, 2016
- Analytical Modeling of Inertial and Droop Responses From a Wind Farm for Short-Term Frequency Regulation in Power SystemsIEEE Transactions on Power Systems, 2015
- Primary frequency regulation by deloaded wind turbines using variable droopIEEE Transactions on Power Systems, 2012
- Three Control Strategies to Improve the Microgrid Transient Dynamic Response During Isolated Mode: A Comparative StudyIEEE Transactions on Industrial Electronics, 2012
- Optimal Power Flow Solution Incorporating Wind PowerIEEE Systems Journal, 2011
- Enhancing Frequency Response Control by DFIGs in the High Wind Penetrated Power SystemsIEEE Transactions on Power Systems, 2010
- Primary load-frequency control from pitch-controlled wind turbines2009
- Participation of Doubly Fed Induction Wind Generators in System Frequency RegulationIEEE Transactions on Power Systems, 2007
- Optimum Generation Control in Wind Parks When Carrying Out System Operator RequestsIEEE Transactions on Power Systems, 2006