Comparison of the Clinical Use of Macintosh and Miller Laryngoscopes for Orotracheal Intubation by Second-Month Nurse Students in Anesthesiology
Open Access
- 22 March 2010
- journal article
- research article
- Published by Hindawi Limited in Anesthesiology Research and Practice
- Vol. 2010
Abstract
Aim. The aim of this study is to compare the clinical feasibility of Macintosh and Miller laryngoscopes for tracheal intubation in non-experienced users in anesthetized patients.Patients and Methods. 119 patients were randomized into the Macintosh group (59) and the Miller group (60). The primary outcome variable was successful tracheal intubation. The secondary outcome variables were number of insertion attempt, intubation time needed, total time to intubation, hemodynamic change and complications.Results. All patients were successfully intubated using the Macintosh, whereas 13 patients (21.6%) were failed with the Miller (). The Macintosh significantly reduced the mean total time to intubation (). There were significant differences in the mean blood pressure at 2 minutes after laryngoscope insertion, immediately, and 2 minutes after tracheal intubation and in the mean heart rate at the laryngoscope insertion, immediately, and at 2 minutes after tracheal intubation between the two groups. Overall complications in both were not significantly different.Conclusion. Orotracheal intubation using the Macintosh is an effective and safe technique in non-experienced hands with significantly increased success rate as well as decreased mean total time to intubation as compare to the Miller. However, these intubations only apply to selected patients deemed to have normal airways.Keywords
This publication has 12 references indexed in Scilit:
- A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin studyAnaesthesia, 2009
- Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airways – a manikin study*Anaesthesia, 2009
- Laryngoscopy via Macintosh Blade versus GlideScopeAnesthesiology, 2009
- Defining the Learning Curve for Paramedic Student Endotracheal IntubationPrehospital Emergency Care, 2005
- Straight blades improve visualization of the larynx while curved blades increase ease of intubation: a comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview bladesCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2003
- Laryngoscopic IntubationAnesthesiology, 2003
- Combined use of esmolol and nicardipine to blunt the haemodynamic changes following laryngoscopy and tracheal intubation*Anaesthesia, 2002
- Laryngoscopy using the McCoy laryngoscope after application of a cervical collarAnaesthesia, 1996
- A NEW LARYNGOSCOPEThe Lancet, 1943
- TECHNIQUE IN ENDOTRACHEAL ANAESTHESIABMJ, 1930