Use of effective dose
Open Access
- 15 March 2016
- journal article
- research article
- Published by SAGE Publications in Annals of the ICRP
- Vol. 45 (1_suppl) , 215-224
Abstract
International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of protection principles. However, questions have arisen regarding practical applications, and a Task Group has been set up to consider issues of concern. This paper focusses on two key proposals developed by the Task Group that are under consideration by ICRP: (1) confusion will be avoided if equivalent dose is no longer used as a protection quantity, but regarded as an intermediate step in the calculation of effective dose. It would be more appropriate for limits for the avoidance of deterministic effects to the hands and feet, lens of the eye, and skin, to be set in terms of the quantity, absorbed dose (Gy) rather than equivalent dose (Sv). (2) Effective dose is in widespread use in medical practice as a measure of risk, thereby going beyond its intended purpose. While doses incurred at low levels of exposure may be measured or assessed with reasonable reliability, health effects have not been demonstrated reliably at such levels but are inferred. However, bearing in mind the uncertainties associated with risk projection to low doses or low dose rates, it may be considered reasonable to use effective dose as a rough indicator of possible risk, with the additional consideration of variation in risk with age, sex and population group.Keywords
This publication has 22 references indexed in Scilit:
- Use of effective dose in medicineAnnals of the ICRP, 2015
- Genomic Instability and Radiation Risk in Molecular Pathways to Colon CancerPLOS ONE, 2014
- Paediatric head CT scan and subsequent risk of malignancy and benign brain tumour: a nation-wide population-based cohort studyBritish Journal of Cancer, 2014
- Radiological protection issues arising during and after the Fukushima nuclear reactor accidentJournal of Radiological Protection, 2013
- We can do better than effective dose for estimating or comparing low-dose radiation risksAnnals of the ICRP, 2012
- Effective dose and risks from medical x-ray proceduresAnnals of the ICRP, 2012
- Effective dose: a flawed concept that could and should be replaced. Comments on a paper by D J Brenner (Br J Radiol 2008;81:521–3)British Journal of Radiology, 2009
- Effective dose: a flawed concept that could and should be replacedBritish Journal of Radiology, 2008
- Effective dose: how should it be applied to medical exposures?British Journal of Radiology, 2007
- Assessing dose of the representative person for the purpose of radiation protection of the publicAnnals of the ICRP, 2006