Abstract
With the increasing number of interventional cardiology procedures, the number of cardiac device infections (including pacemakers, prosthetic valves, coronary and aortic stents) have also increased. These infections can cause significant morbidity and can even lead to mortality if not managed promptly. If suspected clinically the first-line imaging modality is Trans-Thoracic Echocardiography, while Transesophageal Echocardiography is also used in selected cases. The confirmation of a cardiac device infection is mostly done with the help of blood or pus culture. Even though Echocardiography is a very efficient technique for the evaluation of the heart, it cannot differentiate infection from thrombus or fibrosis. With the increasing availability of Positron Emission Tomography CT (PET CT) machines worldwide, the use of 18F-FDG PET CT for infection imaging has gained traction, especially for cardiac device infection. Most of the recent studies show a good diagnostic accuracy of 18F-FDG PET CT with many of the recent diagnostic and management guidelines now acknowledging its role, especially in equivocal cases. We present six such cases where 18F-FDG PET CT provided valuable information either for diagnosis, confirming the presence of infection, delineating extent, therapy response or sometimes even helping appropriate treatment decision making in patients with suspected cardiac device infection.Keywords
This publication has 26 references indexed in Scilit:
- Multicenter experience with extraction of the Riata/Riata ST ICD leadHeart Rhythm, 2014
- Significant suppression of myocardial 18F-fluorodeoxyglucose uptake using 24-h carbohydrate restriction and a low-carbohydrate, high-fat dietJournal of Cardiology, 2013
- Usefulness of Fluorine-18 Positron Emission Tomography/Computed Tomography for Identification of Cardiovascular Implantable Electronic Device InfectionsJACC, 2012
- Coronary stent infections: a case report and literature review.2012
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Permanent Pacemaker and Implantable Cardioverter Defibrillator InfectionArchives of internal medicine (1960), 2007
- Diagnosis and management of staphylococcal infections of pacemakers and cardiac defibrillatorsInternal Medicine Journal, 2005