Three‐dimensional time‐of‐flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG‐triggering: Application to renal arteries
Authors:
- John P. MuglerJMJohn P. Mugler
- 1 April 1994
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 31 (4) , 414-422
Abstract
A three‐dimensional (3D), ECG‐triggered, selective inversion recovery (SIR) rapid gradient‐echo (RAGE) technique is proposed to obtain MR angiograms of the main renal arteries. By using the selective inversion recovery and fat saturation, the background is significantly suppressed while blood maintains a high signal intensity as compared with conventional 3D time‐of‐flight (TOF) MR angiography. The sequence is ECG‐triggered so that blood in‐flow is maximized during systole, and intravoxel dephasing and pulsatile flow artifacts are minimized by collecting data during diastole. As a result, vessel boundary blurring and ghosting artifacts due to background motion are dramatically reduced, and the conspicuity and lumen definition of the arteries are significantly improved. High‐quality MR angiograms of the main renal arteries with excellent blood/tissue contrast and suppression of motion artifacts have been consistently obtained for normal volunteers, with the length of visualization being 51 ± 07 mm for the left, and 57 ± 06 mm for the right renal arteries, significantly greater than using conventional 3D TOF pulse sequences. Statistical analysis was performed by using a one‐sided Student's t test. Key words: renal artery; MR angiography; three‐dimensional MR imaging.Keywords
This publication has 24 references indexed in Scilit:
- Renal arterial stenoses: spiral CT angiography.Radiology, 1993
- Magnetic Resonance Angiography and Detection of Renal Artery Stenosis in a Patient With Impaired Renal FunctionMayo Clinic Proceedings, 1993
- Imaging of the renal arteries: value of MR angiography.American Journal of Roentgenology, 1991
- Fast time-of-flight MR angiography with improved background suppression.Radiology, 1991
- Role of duplex scanning for the detection of atherosclerotic renal artery diseaseKidney International, 1991
- Three-dimensional time-of-flight MR angiography: applications in the abdomen and thorax.Radiology, 1991
- Magnetic resonance angiography of abdominal vessels: early experience using the three-dimensional phase-contrast techniqueBritish Journal of Radiology, 1991
- Two- and Three-Dimensional Phase Contrast MR Angiography of the AbdomenJournal of Computer Assisted Tomography, 1990
- Abdominal aorta and renal artery stenosis: evaluation with MR angiography.Radiology, 1990
- Projective Imaging of Pulsatile Flow with Magnetic ResonanceScience, 1985