Abstract
A battery thermal management system (BTMS) with functions of heat dissipation and heating by using only one liquid and one structure was studied, and a design for a new type of thermal management device structure was proposed. To find the influence factors of the BTMS on heat dissipation and heating characteristics, we selected and simulated three parameters: inlet size, liquid flow rate, and temperature. The convective heat transfer coefficient h and the Nusselt number Nu were used to analyze the influence of inlet size and liquid velocity on heat transfer intensity. The results show that: (1) In the temperature environment of 298 K with different discharge rates, a pipe diameter of 10 mm is the best size of the BTMS; (2) The increase in flow rate can increase the convective heat transfer coefficient h and the Nusselt number Nu. When the flow rate is 0.02 m/s, the growth rate of h and Nu is the largest; (3) The higher the fluid temperature, the faster the temperature of the battery pack increases in cold environments, but the uneven surface temperature of the battery is also more obvious.
Funding Information
  • Research on the Integrated Control Method of the Lateral Stability of Distributed Drive Mining Electric Vehicles (51974229)
  • The 2021 Youth Innovation Team Construction Scientific Research Program of Shaanxi Provincial Education Department (21JP071)