Rebound Tonometry over Soft Contact Lenses
Open Access
- 1 January 2020
- journal article
- research article
- Published by ScopeMed in Acta Informatica Medica
- Vol. 28 (3) , 185-189
Abstract
Goldmann applanation tonometry (GAT) is named as a gold standard for intraocular pressure (IOP) measurement. To assess the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over hydrogel and silicone hydrogel contact lenses (CLs) of different powers. This study included 117 eyes of 61 patients (12 male, 49 female), all habitual wearers of hydrogel and silicone hydrogel CLs, and none previously diagnosed with glaucoma, ocular hypertension or anterior surface disease. Five IOP measurements were taken over each eye using a rebound tonometer (Icare): with soft CLs in situ and then repeated without CLs. Lens power ranged from -9.50 to +10.00 spherical diopters and to a maximum of -0.75 cylinder diopters. A significant positive correlation was found between IOP measurements with and without CLs. The difference between IOP measurements with (mean 20.74±5.19 mmHg) and without (mean 18.79±4.36 mmHg) CLs was found to be 1.95 mmHg (P <0.01). Statistical analysis was performed using the paired t-test and a correlation coefficient was calculated (r = 0.59; P <0.001). We have observed that increase in central corneal thickness (CCT) correlates positively with increase of measurement error of rebound tonometry (r = 0.43; P <0.001). We have shown good reliability of IOP measurements over CLs of different materials and thickness profiles while using rebound tonometer which makes it a feasible and accurate method for clinical purposes.Keywords
This publication has 22 references indexed in Scilit:
- The measurement of intraocular pressure over positive soft contact lenses by rebound tonometryJournal of Optometry, 2016
- Home assessment of diurnal intraocular pressure in healthy children using the Icare rebound tonometerJournal of American Association for Pediatric Ophthalmology and Strabismus, 2012
- Castroviejo Lecture 2009: 40 Years in Search of the Perfect Contact LensCornea, 2010
- Clinical Comparison of the Icare Tonometer and Goldmann Applanation TonometryJournal of Glaucoma, 2008
- Agreement of Rebound Tonometer in Measuring Intraocular Pressure With Three Types of Applanation TonometersAmerican Journal of Ophthalmology, 2006
- Comparison of ICare Tonometer with Goldmann Applanation Tonometer in Glaucoma PatientsJournal of Glaucoma, 2006
- Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal populationOphthalmic and Physiological Optics, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005
- A new induction‐based impact method for measuring intraocular pressureActa Ophthalmologica Scandinavica, 2000
- Über ApplanationstonometrieOphthalmologica, 1957