Red Cell Suspensions in SAGM Medium Further Experience of in vivo Survival of Red Cells, Clinical Usefulness and Plasma‐Saving Effects1
Authors:
- 1 September 1983
- journal article
- research article
- Published by Wiley in Vox Sanguinis
- Vol. 45 (3) , 217-223
Abstract
Red cells depleted of buffy coat and more than 90% of the plasma were suspended and stored in a medium composed of sodium chloride, adenine, glucose and man‐nitol (SAGM). The 24‐hour posttransfusion survival of 51Cr‐labeled red cells was 83.5 ± 5.3% (n = 4) after storage for 35 days and 77.4 ± 4.7%o (n = 6) after 42 days. No abnormal in vivo hemolysis occurred as judged from posttransfusion haptoglobin consumption studies. No abnormal body temperature elevation was found at continuous pertrans‐fusion recordings. The frequency of febrile or urticaria1 transfusion reactions was 0.19% as compared to 0.68% during a whole‐blood transfusion period. Since a mean of 280 ml of plasma can be collected from each blood unit the plasma‐saving effects of the system are considerable. Favorable large‐scale clinical experience is reported.Keywords
This publication has 5 references indexed in Scilit:
- HAEMOTHERAPY WITH RED-CELL CONCENTRATES AND A NEW RED-CELL STORAGE MEDIUMThe Lancet, 1983
- Febrile Transfusion Reactions Reduced by Use of Buffy‐Coat‐Poor Erythrocyte ConcentratesVox Sanguinis, 1982
- Red Cell Preservation in Protein‐Poor Media: III. Protection Against in vitro HemolysisVox Sanguinis, 1981
- Preservation of Human Erythrocytes in the Liquid State: Biological Results with a New MediumVox Sanguinis, 1980
- Clinical Usefulness of Red Cells Preserved in Protein-Poor MediumsNew England Journal of Medicine, 1978