A new large solid angle multi-element silicon drift detector system for low energy X-ray fluorescence spectroscopy
- 1 March 2018
- journal article
- conference paper
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (03) , C03032
Abstract
Low-energy X-ray fluorescence (LEXRF) is an essential tool for bio-related research of organic samples, whose composition is dominated by light elements. Working at energies below 2 keV and being able to detect fluorescence photons of lightweight elements such as carbon (277 eV) is still a challenge, since it requires in-vacuum operations to avoid in-air photon absorption. Moreover, the detectors must have a thin entrance window and collect photons at an angle of incidence near 90 degrees to minimize the absorption by the protective coating. Considering the low fluorescence yield of light elements, it is important to cover a substantial part of the solid angle detecting ideally all emitted X-ray fluorescence (XRF) photons. Furthermore, the energy resolution of the detection system should be close to the Fano limit in order to discriminate elements whose XRF emission lines are often very close within the energy spectra. To ensure all these features, a system consisting of four monolithic multi-element silicon drift detectors was developed. The use of four separate detector units allows optimizing the incidence angle on all the sensor elements. The multi-element approach in turn provides a lower leakage current on each anode, which, in combination with ultra-low noise preamplifiers, is necessary to achieve an energy resolution close to the Fano limit. The potential of the new detection system and its applicability for typical LEXRF applications has been proved on the Elettra TwinMic beamline.Keywords
This publication has 13 references indexed in Scilit:
- Recent developments in Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- First results of a novel Silicon Drift Detector array designed for low energy X-ray fluorescence spectroscopyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterizationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- X-Ray Silicon Drift Detector–CMOS Front-End System with High Energy Resolution at Room TemperatureIEEE Transactions on Nuclear Science, 2016
- Differential protein folding and chemical changes in lung tissues exposed to asbestos or particulatesScientific Reports, 2015
- A CMOS Charge Sensitive Amplifier with sub-electron equivalent noise charge2014
- Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissuesParticle and Fibre Toxicology, 2011
- Noise Minimization of MOSFET Input Charge Amplifiers Based on $\Delta\mu$ and $\Delta{\rm N}$$1/f$ ModelsIEEE Transactions on Nuclear Science, 2009
- Progress in ultra-low-noise ASICs for radiation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Semiconductor drift chamber — An application of a novel charge transport schemeNuclear Instruments and Methods in Physics Research, 1984