Producing persistent, high-current, high-duty-factor H− beams for routine 1 MW operation of Spallation Neutron Source (invited)
- 1 February 2012
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02A732
Abstract
Since 2009, the Spallation Neutron Source (SNS) has been producing neutrons with ion beam powers near 1 MW, which requires the extraction of ∼50 mA H− ions from the ion source with a ∼5% duty factor. The 50 mA are achieved after an initial dose of ∼3 mg of Cs and heating the Cs collar to ∼170 °C. The 50 mA normally persist for the entire 4-week source service cycles. Fundamental processes are reviewed to elucidate the persistence of the SNS H− beams without a steady feed of Cs and why the Cs collar temperature may have to be kept near 170 °C.Keywords
Funding Information
- U.S. Department of Energy (DE-AC05-00OR22725)
This publication has 9 references indexed in Scilit:
- Low-energy beam transport studies supporting the spallation neutron source 1-MW beam operationReview of Scientific Instruments, 2012
- Towards Understanding the Cesium Cycle of the Persistent H[sup −] Beams at SNSAIP Conference Proceedings, 2011
- Ramping up the Spallation Neutron Source beam power with the H− source using 0 mg Cs/dayReview of Scientific Instruments, 2010
- Ramping Up the SNS Beam Power with the LBNL Baseline H[sup −] Source2009
- Volume production negative hydrogen ion sourcesIEEE Transactions on Plasma Science, 2005
- Design, Operational Experiences and Beam Results Obtained with the SNS H− Ion Source and LEBT at Berkeley LabAIP Conference Proceedings, 2002
- An analytical formula and important parameters for low-energy ion sputteringJournal of Applied Physics, 1980
- Molecular beam study of the desorption of cesium ions from tungsten crystalsSurface Science, 1972
- Atomic and Ionic Impact Phenomena on Metal Surfaces1965