Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear Loads
Authors:
- 7 March 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 26 (9) , 2662-2675
Abstract
This paper proposes a new control strategy of effective fifth and seventh harmonic elimination in the stator output voltage at the point of common coupling for a stand-alone doubly fed induction generator (DFIG) feeding a three-phase diode rectifier. This load regularly causes such harmonic distortions, which harmfully affect the performance of other loads connected to the DFIG. In order to allow the DFIG to deliver a pure sinusoidal stator output voltage, these harmonics must be rejected. The proposed elimination method is investigated based on the rotor current controller employing a proportional integral and a resonant controller, which is implemented in the fundamental reference frame. In this frame, both positive seventh and negative fifth voltage harmonic can be eliminated by using only single resonant compensator tuned at six multiples of synchronous frequency in the rotor current controller. The control scheme is developed in the rotor-side converter for the control and operation of the DFIG. Simulations and experimental results with 2.2-kW DFIG feeding a nonlinear load are shown to verify prominent features of the proposed control method.Keywords
This publication has 24 references indexed in Scilit:
- An Improved Control Strategy Using a PI-Resonant Controller for an Unbalanced Stand-Alone Doubly-Fed Induction GeneratorJournal of Power Electronics, 2010
- Adaptive Observer for Sensorless Control of Stand-Alone Doubly Fed Induction GeneratorIEEE Transactions on Industrial Electronics, 2009
- Improved Direct Power Control of a DFIG-Based Wind Turbine During Network UnbalanceIEEE Transactions on Power Electronics, 2009
- Sensorless Maximum Power Point Tracking of Wind by DFIG Using Rotor Position Phase Lock Loop (PLL)IEEE Transactions on Power Electronics, 2009
- Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage ConditionIEEE Transactions on Energy Conversion, 2009
- DFIG-Based Power Generation System With UPS Function for Variable-Speed ApplicationsIEEE Transactions on Industrial Electronics, 2008
- Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone GridIEEE Transactions on Industrial Electronics, 2008
- Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction GeneratorsIEEE Transactions on Energy Conversion, 2007
- Design of an output LC filter for a doubly fed induction generator supplying non-linear loads for aircraft applications2004
- A doubly fed induction generator usingback-to-back PWM converterssupplying an isolated load from a variable speed wind turbineIEE Proceedings - Electric Power Applications, 1996