Variability of digitized left ventricular M‐mode echocardiography: a study in healthy subjects and patients with repaired tetralogy of Fallot
Authors:
- 1 July 1993
- journal article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 13 (4) , 373-383
Abstract
To assess possible factors affecting the variability of digitized left ventricular M-mode echocardiograms, the influence of respiration and the variability due to different beats and observers were analysed in 11 healthy subjects and 11 patients with repaired tetralogy of Fallot. Left ventricular end-diastolic dimension (LVEDD) decreased from end-expiration to end-inspiration in the healthy subjects, but not in the patients. The maximal rate of dimension change decreased in both healthy subjects and patients from end-expiration to end-inspiration. The beat-to-beat variability assessed by the coefficient of variation (CV,%) between measurements of one cardiac cycle was twice the CV for three cycles, whereas the CV for three and five cardiac cycles was not different. The CV for intraobserver variability was less than 5.0% for dimensions and less than 13.0% for the rates of dimension change, whereas the interobserver variability had CV of 17.1% for rates of dimension changes. The influence of respiration and different observers on the variability of LV end-systolic dimension and shortening fraction was larger in the patients than in the healthy subjects. Thus, to obtain optimal technique for analysis of digitized LV M-mode echocardiograms in serial patient studies, the number of observers should be kept at a minimum and at least 3 beats at end-expiration should be used.Keywords
This publication has 21 references indexed in Scilit:
- Importance of adjusting left ventricular diastolic peak filling rate for heart rateThe American Journal of Cardiology, 1988
- Left ventricular systolic and diastolic function after total correction of tetralogy of FallotThe American Journal of Cardiology, 1987
- Digitized echocardiographic measurements of left ventricular function: reproducibility and physiological factors influencing the methodClinical Physiology and Functional Imaging, 1987
- A new use for M-mode echocardiography in detecting left ventricular diastolic dysfunction in coronary artery diseaseThe American Journal of Cardiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effects of spontaneous respiration on left ventricular function assessed by echocardiography.Circulation, 1984
- Variability of digitized echocardiography: Size, source, and means of reductionThe American Journal of Cardiology, 1983
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978
- Effect of phasic respiration on left ventricular dimension and performance in a normal population. An echocardiographic study.Circulation, 1978
- Measurement of peak rates of left ventricular wall movement in man. Comparison of echocardiography with angiography.Heart, 1975