Cyclic and radial variation of the Doppler power from porcine whole blood
Authors:
- Dong-Guk PaengDPDong-Guk Paeng
- K.K. ShungKSK.K. Shung
- 9 July 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (6) , 614-622
Abstract
The Doppler power from porcine blood was observed in a mock flow loop to have cyclic and radial variation during a pulsatile cycle. It was found to decrease with shear rate under steady flow, except near the center of the tube at which other mechanisms such as the effects of radial distribution on the rouleaux might be involved. Under pulsatile flow, the timing of the peak of the Doppler power measured at the center of the tube became closer to the peak systole from 20 to 60 beats/minute (BPM), and the power and velocity peaks coincided at 60 BPM. The overall radial variation of the Doppler power during a whole pulsatile cycle was prominent due to the increase of shear rate from the center to 4.5 mm radial position within a tube of 6.35 mm radius. The cyclic variation of the Doppler power varied with the radial position, being relatively large at the center, reaching a minimum at an intermediate radial Position, and increasing again near the wall. The peak of the Doppler power occurred at early systole near the tube wall and lagged the flow closer to the center. The "black hole" phenomenon was observed only over portions of the flow cycle. All these complex variations of the Doppler power across the tube over a cycle are thought to be the result of red cell aggregation, which can be affected by shear rate and acceleration.Keywords
This publication has 25 references indexed in Scilit:
- High-frequency backscatter and attenuation measurements of porcine erythrocyte suspensions between 30–90 MHzUltrasound in Medicine & Biology, 2002
- Doppler power variation from porcine blood under steady and pulsatile flowUltrasound in Medicine & Biology, 2001
- Ultrasonic backscattering from porcine whole blood of varying hematocrit and shear rate under pulsatile flowUltrasound in Medicine & Biology, 1999
- Characterization of red blood cell aggregate formation using an analytical model of the ultrasonic backscattering coefficientIEEE Transactions on Biomedical Engineering, 1997
- Origin of the Doppler ultrasound spectrum from bloodIEEE Transactions on Biomedical Engineering, 1996
- Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregationIEEE Transactions on Biomedical Engineering, 1996
- Polydisperse scattering theory and comparisons with data for red blood cellsThe Journal of the Acoustical Society of America, 1991
- Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentrationThe Journal of the Acoustical Society of America, 1988
- Effect of flow disturbance on ultrasonic backscatter from bloodThe Journal of the Acoustical Society of America, 1984
- Laminar-Turbulent Transition Process in Pulsatile FlowCirculation Research, 1966