DBA/2J mouse model for experimental glaucoma: pitfalls and problems
- 13 June 2017
- journal article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 45 (9) , 911-922
Abstract
Background: The DBA/2J mouse has been described as a model for congenital experimental glaucoma. It develops anterior segment anomalies with synechiae and pigment dispersion leading to raised intraocular pressure and glaucomatous damage. However, there are serious practical considerations when using this model in longitudinal studies.Methods: We followed 118 mice from 12–48 weeks of age in a pharmaceutical trial. Here we report on the findings in control animals (n = 37). Intraocular pressure was measured weekly, electrophysiology and optical coherence tomography every 6 weeks. A subset also had invasive intraocular pressure measurements performed prior to euthanasia.Results: Although intraocular pressure eventually rose by 9 months in most animals, tonometry was complicated by corneal calcification in the majority of animals rendering intraocular pressure measurement unreliable. Invasive intraocular pressure did not correlate with non‐invasive measures. Loss of scotopic threshold response and thinning of inner retinal layers on optical coherence tomography was observed over time, suggesting glaucomatous damage, but this occurred in some animals without raised intraocular pressure. Poor pupil dilation significantly affected electrophysiology, optical coherence tomography and fundus imaging; 22% of animals developed major systemic complications leading to high dropout rate.Conclusions: The DBA/2J experimental glaucoma model shows variability in expression, and its pathological changes cause major difficulties in assessing disease progression. From our experience, the model presents significant challenges for drug studies in glaucoma, as there are many confounding factors: difficulty with accurate intraocular pressure measurement, in vivo imaging, and electrophysiology recording and a high dropout rate. In addition, there may be an underlying neurodegenerative process independent of intraocular pressure.Keywords
Funding Information
- Novartis Pharmaceuticals Australia (GT-01076)
This publication has 43 references indexed in Scilit:
- Use of Optical Coherence Tomography and Electroretinography to Evaluate Retinal Pathology in a Mouse Model of Autoimmune UveitisPLOS ONE, 2013
- Postnatal Elongation of Eye Size in DBA/2J Mice Compared with C57BL/6J Mice: In Vivo Analysis with Whole-Eye OCTInvestigative Ophthalmology & Visual Science, 2011
- Differential susceptibility to experimental glaucoma among 3 mouse strains using bead and viscoelastic injectionExperimental Eye Research, 2010
- The Microbead Occlusion Model: A Paradigm for Induced Ocular Hypertension in Rats and MiceInvestigative Ophthalmology & Visual Science, 2010
- Head-up tilt lowers IOP and improves RGC dysfunction in glaucomatous DBA/2J miceExperimental Eye Research, 2009
- Spectral Domain Optical Coherence Tomography in Mouse Models of Retinal DegenerationInvestigative Ophthalmology & Visual Science, 2009
- Electrophysiological deficits in the retina of the DBA/2J mouseDocumenta Ophthalmologica, 2009
- Mouse models of retinal ganglion cell death and glaucomaExperimental Eye Research, 2009
- Longitudinal Evaluation of Retinal Ganglion Cell Function and IOP in the DBA/2J Mouse Model of GlaucomaInvestigative Ophthalmology & Visual Science, 2007
- Central Corneal Thickness Correlated with Glaucoma Damage and Rate of ProgressionInvestigative Ophthalmology & Visual Science, 2005