Evaluation of Body Motion by Optical Flow Analysis
Authors:
- Kazuki NakajimaKNKazuki Nakajima
- Hidetoshi MiikeHMHidetoshi Miike
- 1 May 1997
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 36 (5R)
Abstract
For quantitative evaluation of body motion, a fully noncontact and unconstraining monitoring method was developed by introducing image sequence analysis. A spatiotemporal local optimization method was applied to determine optical flow in the image sequence. The optical flow visualized the apparent velocity field of the entire body motion, including both breast movement of respiration and posture changes in a bed. The experiment was carried out under regulated posture changes and under a sleeping condition by measuring heart rate, respiration and digitized image sequences using a video camera. A temporal increase in heart rate reflected the magnitude of physical activities. We proposed two candidate parameters for evaluation of respiratory and physical activities based on comparison among experimental results. The average of squared motion velocities reflected the magnitude of physical activities. The representative field-averaged component showed a waveform with periodic fluctuation corresponding to that of respiration obtained with a nasal thermistor.Keywords
This publication has 11 references indexed in Scilit:
- Detection of apparent skin motion using optical flow analysis: Blood pulsation signal obtained from optical flow sequenceReview of Scientific Instruments, 1997
- Detection of Physiological Parameters without Any Physical Constraints in Bed Using Sequential Image Processing*Japanese Journal of Applied Physics, 1996
- Important influence of respiration on human R-R interval power spectra is largely ignoredJournal of Applied Physiology, 1993
- A system for monitoring temperature distribution in bed and its application to the assessment of body movementPhysiological Measurement, 1993
- Exercise standards. A statement for health professionals from the American Heart Association.Circulation, 1990
- Multichannel Bed Temperature Recorder as a Monitor of Pressure SoresJournal of Clinical Engineering, 1990
- Optical Flow Estimation: An Error Analysis of Gradient-Based Methods with Local OptimizationIEEE Transactions on Pattern Analysis and Machine Intelligence, 1987
- Monitoring the mobility of patients in bedMedical & Biological Engineering & Computing, 1985
- Transducer design and placement for activity recordingMedical & Biological Engineering & Computing, 1982
- Determining optical flowArtificial Intelligence, 1981