Clinical, Anatomical, and Technical Risk Factors for Postoperative Pacemaker or Defibrillator Lead Perforation with Particular Focus on Myocardial Thickness
- 30 May 2014
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 37 (10) , 1291-1296
Abstract
Background: Postoperative lead perforation is a life‐threatening complication of cardiac pacing. Identification of precipitating factors for this serious complication may help to anticipate a specific risk profile and to minimize the incidence.Methods: We conducted a retrospective tertiary referral center analysis to clarify clinical, anatomical, and technical characteristics related to pacemaker (PM) and cardioverter/defibrillator lead perforation.We examined the baseline characteristics and the symptoms. In a subgroup, we investigated the myocardial thickness on contrast‐enhanced cardiac computed tomography.Results: We enrolled 26 patients. Female gender appears to put patients at slightly increased risk for lead perforation. In a majority active fixation leads were used. Symptoms occurred in 72%. Pericardial effusion and tamponade were present in 38% and 19%, respectively. Sensing was compromised in 65%. A high pacing threshold or exit block occurred in 92%. Myocardial thickness did not differ between patients with or without perforation. In 96%, the perforation was treated by transvenous withdrawal.Conclusion: Chest pain, phrenic stimulation, bad sensing, or exit block early after PM implantation must prompt radiological and echocardiographic evaluation. A missing pericardial effusion particularly late after implantation does not rule out a perforation. Especially active fixating leads have a higher risk of perforation. With cardiac surgery in standby transvenous withdrawal is a safe way to treat lead perforation.Keywords
This publication has 15 references indexed in Scilit:
- Risk factors for lead complications in cardiac pacing: A population-based cohort study of 28,860 Danish patientsHeart Rhythm, 2011
- Delayed ICD Lead Cardiac Perforation: Comparison of Small versus Standard‐Diameter Leads Implanted in a Single CenterPacing and Clinical Electrophysiology, 2011
- Late Perforation by Cardiac Implantable Electronic Device Leads: Clinical Presentation, Diagnostic Clues, and ManagementClinical Cardiology, 2010
- Survival and Appropriate Device Interventions in Recipients of Cardioverter Defibrillators Implanted for the Primary Versus Secondary Prevention of Sudden Cardiac DeathPacing and Clinical Electrophysiology, 2009
- Management of Subacute and Delayed Right Ventricular Perforation With a Pacing or an Implantable Cardioverter-Defibrillator LeadThe American Journal of Cardiology, 2008
- Delayed Defibrillator Lead Perforation: An Increasing PhenomenonPacing and Clinical Electrophysiology, 2007
- Right Ventricular Perforation with an ICD Defibrillation Lead Managed by Surgical Revision and Epicardial Leads—Case ReportsPacing and Clinical Electrophysiology, 2007
- Cardiac Tamponade as Complication of Active‐Fixation Atrial Lead Perforations: Proposed Mechanism and Management AlgorithmPacing and Clinical Electrophysiology, 2007
- Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CTPacing and Clinical Electrophysiology, 2007
- Proper Management of Pericardial Tamponade as a Late Complication of Implantable Cardiac Device PlacementThe American Journal of Cardiology, 2006