Dynamic Evaluation of a Digital Wireless Intracranial Pressure Sensor for the Assessment of Traumatic Brain Injury in a Swine Model
Authors:
- 20 November 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 61 (1) , 316-325
Abstract
The monitoring and control of increased intracranial pressure (ICP) are the major requirements for the diagnosis and treatment of patients suffering from traumatic brain injury (TBI) or hydrocephalus. Widely used commercially available ICP measuring devices require the use of a tethered fiber optic probe, which can cause complications, such as infection and hemorrhage. The use of a probe also prohibits immediate (at the time of induced injury) and long-term measurements of ICP. Therefore, we have developed and tested a small fully embedded wireless ICP sensor, incorporating a novel antenna and packaging arrangement. Evaluations were performed in-vitro and in-vivo to demonstrate the robustness of this microwave pressure-monitoring system. This is the first report of in-vivo tests in a dynamic study of continuous (every 6 s) wireless ICP measurements in a swine model of closed-head rotational-acceleration induced TBI using a digital device. In particular, our device measured extreme changes in ICP immediately upon rapid head rotation that persisted for hours after the injury. The readings matched well those obtained from a commercially available tethered monitor. Our device can be utilized in the future as a tool to diagnose and track long-term ICP changes.Keywords
This publication has 26 references indexed in Scilit:
- Transcranial Doppler pulsatility index is not a reliable indicator of intracranial pressure in children with severe traumatic brain injurySurgical Neurology, 2009
- Implantable Wireless Telemetry Boards for In Vivo Transocular TransmissionIEEE Transactions on Microwave Theory and Techniques, 2008
- In-Vitro and In-Vivo Trans-Scalp Evaluation of an Intracranial Pressure Implant at 2.4 GHzIEEE Transactions on Microwave Theory and Techniques, 2008
- Intracranial Pressure MonitoringAACN Advanced Critical Care, 2005
- Microwave industry outlook - wireless communications in healthcareIEEE Transactions on Microwave Theory and Techniques, 2002
- Traumatic Axonal Injury after Closed Head Injury in the Neonatal PigJournal of Neurotrauma, 2002
- An Evaluation of the Camino Ventricular Bolt System in Clinical PracticeNeurosurgery, 1993
- Intracranial pressure monitoring: Fiberoptic monitor compared with the ventricular catheterSurgical Neurology, 1992
- A Clinical Evaluation of the Camino Subdural Screw and Ventricular Monitoring KitsNeurosurgery, 1990
- Continuous monitoring of intracranial pressure with a miniaturized fiberoptic deviceJournal of Neurosurgery, 1987