Intravenous Smart Pumps During Actual Clinical Use
Open Access
- 26 February 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Infusion Nursing
- Vol. 44 (3) , 128-136
Abstract
This descriptive observational study was conducted to increase understanding of medication administration practices during actual clinical use between 2 commonly used, different types of intravenous (IV) smart pumps. Compliance with manufacturer-recommended setup requirements for both primary and secondary infusions and secondary medication administration delay was compared between a head-height differential system and a cassette system. A total of 301 medication administration observations were included in this study: 102 (34%) for the linear peristaltic IV smart pump (medical–surgical: N = 51; critical care: N = 51) and 199 (66%) for the cassette pump (medical–surgical: N = 88; critical care: N = 111). Results found a 0% compliance for primary line setup and 84% compliance for secondary line setup and 1 omitted medication due to a closed clamp with the linear peristaltic system. For the cassette system, there are no head-height requirements. Two roller clamps were found to be in the closed position on initiation of the secondary infusion, but the clinician was alerted by an alarm, so no medication delays occurred. These findings support that the current system requirements for flow rate accuracy using head-height differential systems are difficult to achieve consistently at the point of care. There is a need for additional human factor designed technology to replace manual actions to improve the process of care for nurses and the safety of care for patients.Keywords
This publication has 18 references indexed in Scilit:
- The frequency of intravenous medication administration errors related to smart infusion pumps: a multihospital observational studyBMJ Quality & Safety, 2016
- The antibiotic resistance crisis: part 1: causes and threats.2015
- Benefits and Risks of Using Smart Pumps to Reduce Medication Error Rates: A Systematic ReviewDrug Safety, 2014
- Empiric Antibiotic Treatment Reduces Mortality in Severe Sepsis and Septic Shock From the First HourCritical Care Medicine, 2014
- Evaluation of intravenous medication errors with smart infusion pumps in an academic medical center.2013
- Analysis of risk factors for adverse drug events in critically ill patients*Critical Care Medicine, 2012
- Programmable Infusion Pumps in ICUs: An Analysis of Corresponding Adverse Drug EventsJournal of General Internal Medicine, 2007
- The impact of compliance with 6-hour and 24-hour sepsis bundles on hospital mortality in patients with severe sepsis: a prospective observational studyCritical Care, 2005
- Insights from the sharp end of intravenous medication errors: implications for infusion pump technologyQuality and Safety in Health Care, 2005
- A controlled trial of smart infusion pumps to improve medication safety in critically ill patients*Critical Care Medicine, 2005