Abstract
Air discharge characteristic gas detection is considered as one of the most reliable methods in fault diagnosis of air switchgear. Based on first-principles of density functional theory, the adsorption and sensing properties of transition metal (Cr) modified MoS 2 (001) monolayer on three air discharge characteristic gases (Co, NO, and NO 2 ) are analyzed. Firstly, the Cr doped MoS 2 (001) monolayer model is obtained by modeling and analyzing different doping sites, and the subsequent DFT calculation is done. Based on this model, many kinds of adsorption structures were constructed and optimized. The parameters of adsorption structure, adsorption energy and adsorption distance were obtained. Furthermore, the differential charge density, state density, response performance and adsorption performance of the system were analyzed. The results show that Cr-MoS 2 (001) monolayer has good adsorption performance to three gases. CO gas molecules can be rapidly desorbed from Cr-MoS 2 (001) monolayer surface at room temperature. Cr-MoS 2 (001) monolayer has the potential as a low-power gas sensor material for detecting CO characteristic gases and a solid adsorbent material for cleaning NO and NO 2 gases. This work provides theoretical guidance for the development of MoS 2 -based sensors for detecting characteristic gases in air discharge.
Funding Information
  • National Natural Science Foundation of China (61906160)
  • Natural Science Foundation of Hubei Province (2022CFB941)
  • Sichuan Science and Technology Program (2022NSFSC1632)

This publication has 42 references indexed in Scilit: