High-sensitive measurement of water vapor: shot-noise level performance via a noise canceller
- 8 February 2013
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (5) , 1094-1099
Abstract
Taking advantages of distributed feedback laser diode a technique is described to achieve high-sensitive measurement for water vapor concentration. This technique, with a modified balanced ratio metric detection system, has improved the accuracy of measured absorption spectrum by two main aspects. Improvement by matching equivalent conductivity of signal or reference photo detector (PD) is presented, and with the additional matched resistance suppression for the power variation in the signal-beam has been improved from 53 to 88 dB. The importance of integrating amplifier bandwidth design from the circuit to the measured absorption spectrum has been demonstrated in our experiment. For a scan rate of 32 Hz with an optimal corresponding bandwidth of 15.9 kHz, the absorption spectrum is well described by Voigt profile, with a difference of 1% at an atmosphere pressure of 1 atm and a room temperature of 296 K. With the application of averaging and filtering, absorption sensitivity of for water vapor at 1368.597 nm has been demonstrated, and the corresponding concentration is 71.8 ppb in just a 10 cm path length.
Keywords
Funding Information
- National Natural Science Foundation of China (60977058)
- Shandong Province of China (JQ200819, BS2010DX028)
- Independent Innovation Foundation of Shandong University (IIFSDU2010JC002, 2012JC015)
This publication has 11 references indexed in Scilit:
- Detection of water vapor concentration based on differential value of two adjacent absorption peaksLaser Physics Letters, 2012
- Investigation Into Time Response of Polymer Fiber Bragg Grating Based Humidity SensorsJournal of Lightwave Technology, 2011
- Absolute, high resolution water transpiration rate measurements on single plant leaves via tunable diode laser absorption spectroscopy (TDLAS) at 1.37 μmApplied Physics B, 2008
- Diode laser measurements of line strengths and self-broadening parameters of water vapor between 300 and 1000K near 1.31μmJournal of Quantitative Spectroscopy and Radiative Transfer, 1998
- Ultrasensitive, visible tunable diode laser detection of NO_2Applied Optics, 1996
- Ultrasensitive dual-beam absorption and gain spectroscopy: applications for near-infrared and visible diode laser sensorsApplied Optics, 1995
- Airborne tunable diode laser spectrometer for trace-gas measurement in the lower stratosphereApplied Optics, 1993
- Double-beam laser absorption spectroscopy: shot noise-limited performance at baseband with a novel electronic noise canceler1991
- Shot noise limited optical measurements at baseband with noisy lasers (proceedings Only)1991
- High-sensitivity transient spectroscopy using tunable diode lasersApplied Physics B, 1989