The influence of lubricant temperature on the wear of total knee replacements
Open Access
- 6 September 2023
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in Biosurface and Biotribology
- Vol. 9 (3) , 71-77
Abstract
Experimental in vitro simulation can be used to predict the wear performance of total knee replacements. The in vitro simulation should aim to replicate the in vivo loading, motion and environment experienced by the joint, predicting wear and potential failure whilst minimising test artefacts. Experimental wear simulation can be sensitive to environmental conditions; the environment temperature is one variable which should be controlled and was the focus of this investigation. In this study, the wear of an all‐polymer (PEEK‐OPTIMA™ polymer‐on‐UHMWPE) total knee replacement and a conventional cobalt chrome‐on‐UHMWPE implant of similar initial surface topography and geometry were investigated under elevated temperature conditions. The wear was compared to a previous study of the same implants under simulator running temperature (i.e. without heating the test environment). Under elevated temperature conditions, the wear rate of the UHMWPE tibial inserts was low against both femoral component materials (mean 3 /million cycles) and significantly lower ( p < 0.05) than for investigations at simulator running temperature. Protein precipitation from the lubricant onto the component articulating surfaces is a possible explanation for the lower wear. This study highlights the need to understand the influence of different variables including environmental temperature to minimise the test artefacts during wear simulation which may affect the wear rates.Keywords
Funding Information
- Wellcome Trust (WT 088908/Z/09/Z)
- Engineering and Physical Sciences Research Council (EP/J017620/1, EP/K029592/1)
This publication has 27 references indexed in Scilit:
- Characterization of protein degradation in serum‐based lubricants during simulation wear testing of metal‐on‐metal hip prosthesesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2010
- Sensitivity to implant materials in patients with total knee arthroplastiesBiomaterials, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- A Review of Lubrication Conditions for Wear Simulation in Artificial Hip ReplacementsTribology Transactions, 2006
- Effect of Arthroscopy and Continuous Cryotherapy on the Intra‐articular Temperature of the KneeArthroscopy, 2005
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- Intra-Articular Knee Temperature ChangesThe American Journal of Sports Medicine, 2004
- The effects of lubricant composition on in vitro wear testing of polymeric acetabular componentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip jointsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Conformational change of bovine serum albumin by heat treatmentThe Protein Journal, 1989