Towards Maximizing Hosting Capacity by Optimal Planning of Active and Reactive Power Compensators and Voltage Regulators: Case Study
Open Access
- 16 October 2022
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 13299
Abstract
Improving the performance of distribution systems is one of the main objectives of power system operators. This can be done in several ways, such as network reconfiguration, system reinforcement, and the addition of different types of equipment, such as distributed generation (DG) units, shunt capacitor banks (CBs), and voltage regulators (VRs). In addition, the optimal use of renewable and sustainable energy sources (RSESs) has become crucial for meeting the increase in demand for electricity and reducing greenhouse gas emissions. This requires the development of techno-economic planning models that can measure to what extent modern power systems can host RSESs. This article applies a new optimization technique called RUN to increase hosting capacity (HC) for a rural Egyptian radial feeder system called the Egyptian Talla system (ETS). RUN relies on mathematical concepts and principles of the widely known Runge–Kutta (RK) method to get optimal locations and sizes of DGs, CBs, and VRs. Furthermore, this paper presents a cost-benefit analysis that includes fixed and operating costs of the compensators (DGs, CBs, and VRs), the benefits obtained by reducing the power purchased from the utility, and the active power loss. The current requirements of Egyptian electricity distribution companies are met in the formulated optimization problem to improve the HC of this rural system. Uncertain loading conditions are taken into account in this study. The main load demand clusters are obtained using the soft fuzzy C-means clustering approach according to load consumption patterns in this rural area. The introduced RUN optimization algorithm is used to solve the optimal coordination problem between DGs, CBs, and VRs. Excellent outcomes are obtained with a noteworthy reduction in the distribution network power losses, improvement in the system’s minimum voltage, and improvement of the loading capacity. Several case studies are investigated, and the results prove the efficiency of the introduced RUN-based methodology, in which the probabilistic HC of the system reaches 100% when allowing reverse power flow to the utility. In comparison, this becomes 49% when allowing reverse power to flow back to the utility.Keywords
This publication has 53 references indexed in Scilit:
- Simultaneous allocation of distributed energy resource using improved particle swarm optimizationApplied Energy, 2017
- Simultaneous placement and sizing of DGs and shunt capacitors in distribution systems by using IMDE algorithmInternational Journal of Electrical Power & Energy Systems, 2016
- Distributed Generation Hosting Capacity Evaluation for Distribution Systems Considering the Robust Optimal Operation of OLTC and SVCIEEE Transactions on Sustainable Energy, 2016
- Static VAR Compensator Damping Controller Design Based on Flower Pollination Algorithm for a Multi-machine Power SystemElectric Power Components and Systems, 2015
- A Multi-objective Optimization for Sizing and Placement of Voltage-controlled Distributed Generation Using Supervised Big Bang–Big Crunch MethodElectric Power Components and Systems, 2014
- Energy loss reduction by optimal distributed generation allocation in distribution systemsInternational Transactions on Electrical Energy Systems, 2014
- Optimal penetration levels for inverter-based distributed generation considering harmonic limitsElectric Power Systems Research, 2013
- A direct approach for distribution system load flow solutionsIEEE Transactions on Power Delivery, 2003
- An efficient constraint handling method for genetic algorithmsComputer Methods in Applied Mechanics and Engineering, 2000
- A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated ClustersJournal of Cybernetics, 1973