Analyzing faulted transmission lines: Phase components as an alternative to symmetrical components
Authors:
- 1 March 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-19
Abstract
Protection engineers are often interested in calculating the steady-state voltages and currents on faulted transmission lines. This necessitates the use of accurate fault solution techniques. The most commonly taught and used methods involve symmetrical components. Symmetrical components are advantageous in that they yield multiple decoupled systems that are simple to solve. This simplicity was crucial before the advent of digital computers. With modern computers, it is equally easy to perform calculations with phase components (A, B, C) or with symmetrical components (positive, negative, zero). With symmetrical components, different circuit topologies must be used for different fault types, which can be inconvenient in practice. Additionally, symmetrical component techniques commonly assume line transposition and give oversimplified results for real-life cases. This paper presents phase-domain solution methods as an alternative to symmetrical components. Phase-domain analysis allows all ten common shunt faults to be modeled using a single circuit topology. In exchange for this convenience, the phase-domain approach must account for mutual coupling between the three phases of a transmission line. However, this in turn allows phase-domain analysis to be used to model untransposed transmission lines without compromising the accuracy of the solution. This paper presents a general derivation for a steady-state, phase-domain transmission line solution and illustrates its practical use through several examples. Steady-state signals can be reliably used for testing traditional phasor-based relays. This steady-state solution is then translated into a time-domain equivalent, which numerically solves differential equations to accurately model the transition between prefault and fault states. Accurate modeling of state transitions makes this solution suitable for testing relays that use incremental quantities.Keywords
This publication has 10 references indexed in Scilit:
- Speed of line protection - can we break free of phasor limitations?2015
- Protecting mutually coupled transmission lines: Challenges and solutions2014
- Numerical Methods for Ordinary Differential Equations2008
- Protective Relaying2006
- A phase selection algorithm for an adaptive impedance relay2003
- A combined directional and faulted phase selector element based on incremental quantitiesIEEE Transactions on Power Delivery, 2001
- Characterization of phase and amplitude comparators in UHS directional relaysIEEE Transactions on Power Systems, 1997
- A positive sequence directional element for numerical distance relays1997
- Transient Signals and Their Processing in an Ultra High-Speed Directional Relay for EHV/UHV Transmission Line ProtectionIEEE Transactions on Power Apparatus and Systems, 1985
- Method of Symmetrical Co-Ordinates Applied to the Solution of Polyphase NetworksTransactions of the American Institute of Electrical Engineers, 1918