Limitations of glycated albumin standardization when applied to the assessment of diabetes patients
- 12 June 2024
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (12) , 2526-2533
Abstract
Objectives: Glycated albumin (GA) has potential value in the management of people with diabetes; however, to draw meaningful conclusions between clinical studies it is important that the GA values are comparable. This study investigates the standardization of the Norudia Glycated Albumin and Lucica Glycated Albumin-L methods. Methods: The manufacturer reported imprecision was verified by performing CLSI-EP15-A3 protocol using manufacturer produced controls. The Japanese Clinical Chemistry Reference Material (JCCRM)611-1 was measured 20 times to evaluate the accuracy of both methods. GA was also measured in 1,167 patient samples and results were compared between the methods in mmol/mol and %. Results: Maximum CV for Lucica was ≤0.6 % and for Norudia ≤1.8 % for control material. Results in mmol/mol and % of the JCCRM611-1 were within the uncertainty of the assigned values for both methods. In patient samples the relative difference in mmol/mol between the two methods ranged from −10.4 % at a GA value of 183 mmol/mol to +8.7 % at a GA value of 538 mmol/mol. However, the relative difference expressed in percentage units ranged from of 0 % at a GA value of 9.9 % to +1.7 % at a GA value of 30 %. Conclusions: The results in mmol/mol between the two methods for the patient samples were significantly different compared to the results in %. It is not clear why patient samples behave differently compared to JCCRM611-1 material. Valuable lessons can be learnt from comparing the standardization process of GA with that of HbA1c.Keywords
This publication has 20 references indexed in Scilit:
- Development of a matrix-based candidate reference material for human glycated albumin using isotope-dilution liquid chromatography/tandem mass spectrometryAnalytica Chimica Acta, 2022
- Progressive loss of corneal nerve fibers is associated with physical inactivity and glucose lowering medication associated with weight gain in type 2 diabetesJournal of Diabetes Investigation, 2022
- Analytical performances of a glycated albumin assay that is traceable to standard reference materials and reference range determinationJournal of Clinical Laboratory Analysis, 2022
- Glycation of albumin and its implication in Diabetes: A comprehensive analysis using mass spectrometryClinica Chimica Acta, 2021
- Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determinationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2015
- Utility of glycated albumin for the diagnosis of diabetes mellitus in a Japanese population study: results from the Kyushu and Okinawa Population Study (KOPS)Diabetologia, 2011
- Serum glycated albumin, but not glycated hemoglobin, is low in relation to glycemia in men with hypertriglyceridemiaJournal of Diabetes Investigation, 2010
- Effect of age and race/ethnicity on HbA1c levels in people without known diabetes mellitus: Implications for the diagnosis of diabetesDiabetes Research and Clinical Practice, 2010
- Study of glycated amino acid elimination reaction for an improved enzymatic glycated albumin measurement methodClinica Chimica Acta, 2004
- An enzymatic method for the measurement of glycated albumin in biological samplesClinica Chimica Acta, 2002