Comparison between bilateral implantation of a trifocal intraocular lens (Alcon Acrysof IQ® PanOptix) and extended depth of focus lens (Tecnis® Symfony® ZXR00 lens)
- 10 October 2020
- journal article
- research article
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (2) , 567-573
Abstract
Purpose To compare the visual performance outcomes following bilateral cataract surgery using trifocal intraocular lens (Alcon Acrysof IQ® PanOptix) and extended depth of focus lens (Tecnis® Symfony® ZXR00 lens). Methods In this prospective, non-randomized, comparative trial, a total of 40 subjects (80 eyes) were divided into two different groups and submitted to bilateral cataract surgery and implantation of the two different IOLs, Alcon Acrysof IQ® PanOptix® TNFT00 in group A and Tecnis® Symfony® ZXR00 lens (Johnson & Johnson Vision) in group B, was assessed. The uncorrected and corrected near (33 cm), intermediate (60 cm), and far (4 m) binocular visual acuity was measured, and visual binocular defocus curves were also measured in the photopic condition with a long-distance visual acuity and the qualitative visual function was assessed by NEI VFQ-25. Results Group A comprised 20 patients; 11 women (55%) and 9 men (45%) with a mean age of 62.1 ± 5.4. In group B 20 patients were recruited; 12 women (60%) and 8 men (40%) with a mean age of 63.2 ± 6.1. The postoperatively calculated mean sphere was + 0.35 ± 0.12 D and − 0.14 ± 0.13 D in groups A and B, respectively. The postoperative uncorrected distance visual acuity (UDVA) as well as uncorrected intermediate visual acuity (UIVA) were statistically equal in both groups (P = 0.12, P = 0.17); meanwhile, the postoperative uncorrected near visual acuity (UNVA) was significantly better in patients with PanOptix IOL implantation (P = 0.01) compared to the binocular defocus curve; the results of the PanOptix group were better than the Symfony group in intermediate and near distance (P = 0.089, P = 0.001) and according to the VFQ-25 questionnaire, then ear vision score as well as sum score turned out to be significantly higher in groups A than B (P = 0.001 and P = 0.015, respectively). Conclusion Both strategies were able to provide good vision for far, intermediate and near distances.Keywords
This publication has 15 references indexed in Scilit:
- Clinical outcomes with a diffractive trifocal intraocular lensEuropean Journal of Ophthalmology, 2018
- Treatment of acute ocular chemical burnsSurvey of Ophthalmology, 2018
- Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline LensAmerican Journal of Ophthalmology, 2017
- Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lensesClinical Ophthalmology, 2017
- First implantation of a diffractive quadrafocal (trifocal) intraocular lensJournal of Cataract & Refractive Surgery, 2015
- Multifocal versus monofocal intraocular lenses after cataract extractionSao Paulo Medical Journal, 2015
- Optical bench performance of AcrySof® IQ ReSTOR®, AT LISA® tri, and FineVision® intraocular lensesClinical Ophthalmology, 2014
- Evidence-based guidelines for cataract surgery: Guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery databaseJournal of Cataract & Refractive Surgery, 2012
- Transplanting fragments of diabetic pancreas into activated omentum gives rise to new insulin producing cellsBiochemical and Biophysical Research Communications, 2007
- Psychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ)Archives of Ophthalmology (1950), 1998