Enhancement of Non-Invasive Recording of Electroenterogram by Means of a Flexible Array of Concentric Ring Electrodes
- 14 November 2013
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (3) , 651-660
Abstract
Monitoring intestinal myoelectrical activity by electroenterogram (EEnG) would be of great clinical interest for diagnosing gastrointestinal pathologies and disorders. However, surface EEnG recordings are of very low amplitude and can be severely affected by baseline drifts and respiratory and electrocardiographic (ECG) interference. In this work, a flexible array of concentric ring electrodes was developed and tested to determine whether it can provide surface EEnG signals of better quality than bipolar recordings from conventional disc electrodes. With this aim, sixteen healthy subjects in a fasting state (>8 h) underwent recording. The capability of detecting intestinal pacemaker activity (slow wave) and the influence of physiological interferences were studied. The signals obtained from the concentric ring electrodes proved to be more robust to ECG and respiratory interference than those from conventional disc electrodes. The results also show that intestinal EEnG components such as the slow wave can be more easily identified by the proposed system based on a flexible array of concentric ring electrodes. The developed active electrode array could be a very valuable tool for non-invasive diagnosis of disease states such as ischemia and motility disorders of the small bowel which are known to alter the normal enteric slow wave activity.Keywords
This publication has 28 references indexed in Scilit:
- Automatic Seizure Detection in Rats Using Laplacian EEG and Verification with Human Seizure SignalsAnnals of Biomedical Engineering, 2012
- Tripolar Laplacian electrocardiogram and moment of activation isochronal mappingPhysiological Measurement, 2007
- Adaptive filtering of ECG interference on surface EEnGs based on signal averagingPhysiological Measurement, 2006
- Development of a Tri-polar Concentric Ring Electrode for Acquiring Accurate Laplacian Body Surface PotentialsAnnals of Biomedical Engineering, 2006
- Noninvasive Measurement and Analysis of Intestinal Myoelectrical Activity Using Surface ElectrodesIEEE Transactions on Biomedical Engineering, 2005
- Volume conductor effects on the spatial resolution of magnetic fields and electric potentials from gastrointestinal electrical activityMedical & Biological Engineering & Computing, 2001
- Distension-Induced Myoelectrical Dysrhythmia and Effect of Intestinal Pacing in DogsDigestive Diseases and Sciences, 2000
- The human vector magnetogastrogram and magnetoenterogramIEEE Transactions on Biomedical Engineering, 1999
- Measurement of electrical activity of the human small intestine using surface electrodesIEEE Transactions on Biomedical Engineering, 1993
- Electrical spike activity in the human small intestineDigestive Diseases and Sciences, 1978