Label-Free Comparative Analysis of Proteomics Mixtures Using Chromatographic Alignment of High-Resolution μLC−MS Data
- 12 January 2008
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (4) , 961-971
Abstract
Label-free relative quantitative proteomics is a powerful tool for the survey of protein level changes between two biological samples. We have developed and applied an algorithm using chromatographic alignment of microLC-MS runs to improve the detection of differences between complex protein mixtures. We demonstrate the performance of our software by finding differences in E. coli protein abundance upon induction of the lac operon genes using isopropyl beta-D-thiogalactopyranoside. The use of our alignment gave a 4-fold decrease in mean relative retention time error and a 6-fold increase in the number of statistically significant differences between samples. Using a conservative threshold, we have identified 5290 total microLC-MS regions that have a different abundance between these samples. Of the detected difference regions, only 23% were mapped to MS/MS peptide identifications. We detected 74 proteins that had a greater relative abundance in the induced sample and 21 with a greater abundance in the uninduced sample. We have developed an effective tool for the label-free detection of differences between samples and demonstrate an increased sensitivity following chromatographic alignment.Keywords
This publication has 41 references indexed in Scilit:
- High-Speed Data Reduction, Feature Detection, and MS/MS Spectrum Quality Assessment of Shotgun Proteomics Data Sets Using High-Resolution Mass SpectrometryAnalytical Chemistry, 2007
- A New Algorithm Using Cross-Assignment for Label-Free Quantitation with LC−LTQ-FT MSJournal of Proteome Research, 2007
- Estrogen receptor α is a putative substrate for the BRCA1 ubiquitin ligaseProceedings of the National Academy of Sciences, 2007
- The Universal Protein Resource (UniProt)Nucleic Acids Research, 2006
- Semi-supervised LC/MS alignment for differential proteomicsBioinformatics, 2006
- Signal Maps for Mass Spectrometry-based Comparative ProteomicsMolecular & Cellular Proteomics, 2006
- A Brave New Year!Journal of Proteome Research, 2006
- Systematic Comparison of a Two-dimensional Ion Trap and a Three-dimensional Ion Trap Mass Spectrometer in ProteomicsMolecular & Cellular Proteomics, 2005
- Statistical significance for genomewide studiesProceedings of the National Academy of Sciences of the United States of America, 2003
- Determination of metal ions using ion chromatography and indirect amperometric detectionAnalytical Chemistry, 1987