Saving Tendons on Distal Radius Fractures: A Simple Surgical Pearl to Prevent FPL Tendon Conflict with Volar Locking Plates
- 7 December 2016
- journal article
- procedure
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 06 (03) , 248-250
Abstract
Injury to the flexor pollicis longus (FPL) tendon is one of the most frequent complications when fixing distal radius fractures with the volar locking plates. The author proposed a simple surgical technique providing a reliable soft tissue protection to prevent friction on the FPL with the volar locking plate, using a flap of the FCR sheath sutured to attachments of the volar capsule on the lunate buttress facet of the distal radius.Keywords
This publication has 6 references indexed in Scilit:
- Results of pronator quadratus repair in distal radius fractures to prevent tendon rupturesIndian Journal of Orthopaedics, 2014
- Distal Radius Volar Locking Plate Design and Associated Vulnerability of the Flexor Pollicis LongusThe Journal of Hand Surgery, 2014
- Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literatureJournal of Orthopaedics and Traumatology, 2013
- How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicus longus tendon: a biomechanical investigationJournal of Hand Surgery (European Volume), 2012
- PREVENTION OF FLEXOR POLLICIS LONGUS TENDON RUPTURE AFTER VOLAR PLATE FIXATION OF DISTAL RADIUS FRACTURESHand Surgery, 2011
- Volar Plate Fixation of Distal Radius FracturesHand Clinics, 2005