Robot-Assisted Isolation of the Pulmonary Veins with Microwave Energy
Authors:
- 1 January 2006
- journal article
- research article
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 21 (1) , 83-88
Abstract
Ablation of the left atrium to isolate the pulmonary veins has been shown to interrupt electrical foci that may induce atrial fibrillation. This study evaluated the feasibility of performing a minimally invasive left atrial isolation on a beating heart using the da Vinci Robotic Surgical System and a flexible microwave probe (Flex 10 by AFx, Inc., Fremont, CA, USA), and the reliability of exit block pacing to confirm transmurality of the lesions created. On six canines, the Flex 10 probe was passed around the left atrium posterior to the superior vena cava, through the transverse sinus, and back through the oblique sinus via a right-chest-only approach using the da Vinci Robotic Surgical System. Prior to ablation, pacing outside the atrial cuff was confirmed. Ablation was then carried out on the beating heart and repeated (as needed) until electrical isolation was demonstrated by exit block pacing. Probe position was confirmed at the completion of the procedure via sternotomy. Analysis included acute histologic and gross examination of the targeted area. There was no significant difference (p = 0.110) in procedure time, although it decreased 39.6% from the first three cases to the last three cases. Electrical evidence of electrical left atrial isolation was achieved in all subjects. Acute histologic examination confirmed transmurality inconsistently. Additionally, in two animals, the Flex 10 probe was found to be anterior to the left atrial appendage. All animals survived the procedure. A minimally invasive left atrial isolation procedure using monopolar microwave energy with the da Vinci Robotic Surgical System is simple and feasible. However, despite creating an electrical block, transmurality was not demonstrated consistently and further confirmation of catheter positioning is necessary during a right-chest-only approach.Keywords
This publication has 20 references indexed in Scilit:
- Evaluation of Epicardial Microwave Ablation Lesions: Histology Versus ElectrophysiologyThe Annals of Thoracic Surgery, 2004
- Atrial fibrillation II: rationale for surgical treatmentThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Atrial fibrillation I: a new classification systemThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Robotic atrial septal defect repair and endoscopic treatment of atrial fibrillationSeminars in Thoracic and Cardiovascular Surgery, 2003
- Modification of the Substrate for Maintenance of Idiopathic Human Atrial FibrillationCirculation, 1999
- Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary VeinsCirculation, 1999
- Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping SystemCirculation, 1999
- Right Atrial Focal Atrial FibrillationJournal of Cardiovascular Electrophysiology, 1999
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998
- A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency AblationCirculation, 1997