Delphi consensus recommendations for preventing and treating cardiac implantable electronic device infections beyond current guidelines
Authors:
Open Access
- 22 April 2026
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 13135
Abstract
Infections associated with cardiac implantable electronic devices (CIEDs) pose significant clinical challenges due to their life-threatening nature and complex management. Recent advancements in prevention, diagnosis, and treatment have been driven by landmark trials such as PADIT and WRAP-IT, alongside evolving diagnostic tools like [18 F]FDG PET/CT and updated diagnostic criteria (e.g., 2023 Duke-ISCVID). A combination of well-established approaches—such as leadless pacemakers, subcutaneous ICDs, and an antibiotic-eluting envelope—and evolving adjunctive strategies, including a taurolidine-containing antimicrobial agent, incision drapes, fascial plane blocks or double gloving, have broadened the spectrum of options to reduce and potentially mitigate the risk of CIED infection. While devices like leadless pacemakers, subcutaneous ICDs, and antibiotic envelopes are supported by randomized controlled trials, adjunctive measures such as taurolidine rely predominantly on observational data. To address this variation in the strength of available evidence, a modified Delphi consensus process was conducted, bringing together cardiologists and infectious disease experts to define experience-based best practices in areas where current guidelines offer limited or no specific recommendations. The consensus achieved strong agreement (≥ 80%) on key strategies, including mandatory double-gloving to reduce contamination, the use of validated risk models (e.g., PADIT, BLISTER) for tailored infection prevention employing an antibiotic eluting envelope, multidisciplinary decision-making for non-extractable infections and the use of taurolidine solutions as adjuncts to prevent CIED infection. Moderate consensus (60–79%) supported non-delayed reimplantation after lead-related endocarditis and single-session reimplantation in pacing-dependent patients under specific circumstances. However, no consensus was reached on mandating a minimum annual procedural volume (≥ 500 cases) for CIED centers, reflecting concerns about access and operator expertise. The findings emphasize the importance of personalized risk stratification, procedural innovations, and multidisciplinary collaboration in optimizing CIED infection outcomes. Areas requiring further research include the efficacy of iodophor-impregnated drapes, fascial plane blocks, and taurolidine solutions. This consensus provides a pragmatic framework for clinicians, highlighting evidence-informed strategies to mitigate infection risks and improve care for patients undergoing CIED procedures.Keywords
Funding Information
- Hochschule Bremerhaven
This publication has 31 references indexed in Scilit:
- Adherent skin barrier drape use is associated with a reduced risk of cardiac implantable device infection: Results from a prospective study of 14,225 proceduresHeart Rhythm, 2023
- Herzschrittmacherinfektion bei fragilen PatientenHerzschrittmachertherapie + Elektrophysiologie, 2023
- Use of Taurolidine in a Patient With a Cardiac Implantable Electronic Device ProtrusionJACC: Case Reports, 2023
- Regional Antibiotic Delivery for Implanted Cardiovascular Electronic Device InfectionsJACC, 2023
- Reporting guidelines for Delphi techniques in health sciences: A methodological reviewZeitschrift für Evidenz, Fortbildung und Qualität im Gesundheitswesen, 2022
- Endovascular Removal of Thrombus and Right Heart Masses Using the AngioVac System: Results of 234 Patients from the Prospective, Multicenter Registry of AngioVac Procedures in Detail (RAPID)Journal of Vascular and Interventional Radiology, 2021
- Antibacterial Envelope to Prevent Cardiac Implantable Device InfectionThe New England journal of medicine, 2019
- Prevention of Arrhythmia Device Infection TrialJACC, 2018
- 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extractionHeart Rhythm, 2017
- Double gloving to reduce surgical cross-infectionCochrane Database of Systematic Reviews, 2006