Mid‐term outcomes of computer‐assisted total knee arthroplasty
- 14 January 2011
- journal article
- clinical trial
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (7) , 1107-1112
Abstract
Purpose: The aim of this study is to investigate the clinical results of total knee arthroplasty (TKA) using a navigation system after a minimum of 5 years.Method: Thirty cases of posterior‐stabilized, TKA‐implanted using a computed tomography‐free navigation system were compared with 30 cases having matched TKA of the same type implanted via a classical, manual technique. At mid term, a minimum of 5 years after surgery, Knee Society scores (KSSs), Knee Society Functional scores (KSFSs), range of motion (ROM), and radiographic results of 27 patients in each group were assessed and reported in this study.Results: The accuracy of the implantations in relation to the coronal mechanical axis in the navigation group was superior to that of the manual group (P < 0.01). The femoral rotational profile revealed the prosthesis in the navigation group that was implanted with significantly less internal rotation than the manual group. Mid‐term 5‐year clinical results, including ROMs and KSSs, were significantly better in the navigation group (P < 0.01). KSFSs were equally good in both the groups.Conclusion: Better alignment and similarity of good clinical results at mid‐term follow up may provide patients who receive navigation TKA with long‐term endurance of their implants. Further studies on longer‐term outcomes and functional improvements are required to validate these possibilities.Level of evidence: Prospective comparative study, Level II.Keywords
This publication has 26 references indexed in Scilit:
- Differences between Sagittal Femoral Mechanical and Distal Reference Axes Should Be Considered in Navigated TKAClinical Orthopaedics and Related Research, 2009
- Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up?International Orthopaedics, 2008
- TKA Sagittal Alignment with Navigation Systems and Conventional Techniques Vary Only a Few DegreesClinical Orthopaedics and Related Research, 2008
- Functional comparison of total knee arthroplasty performed with and without a navigation systemInternational Orthopaedics, 2008
- Femoral Shaft Fracture Resulting From Femoral Tracker Placement in Navigated TKAClinical Orthopaedics and Related Research, 2008
- Computer navigation versus conventional implantation for varus knee total arthroplasty: A case-control study at 5 years follow-upThe Knee, 2008
- Alignment and orientation of the components in total knee replacement with and without navigation supportThe Journal of Bone and Joint Surgery. British volume, 2007
- Computer navigation versus conventional total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Consistency of Implantation of a Total Knee Arthroplasty with a Non–Image-Based Navigation SystemThe Journal of Arthroplasty, 2005
- Patient satisfaction after knee arthroplasty: A report on 27,372 knees operated on between 1981 and 1995 in SwedenActa Orthopaedica, 2000