Augmented reality for point-of-care ultrasound-guided vascular access in pediatric patients using Microsoft HoloLens 2: a preliminary evaluation
- 13 September 2024
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 062604-15
Abstract
SignificanceConventional ultrasound-guided vascular access procedures are challenging due to the need for anatomical understanding, precise needle manipulation, and hand–eye coordination. Recently, augmented reality (AR)-based guidance has emerged as an aid to improve procedural efficiency and potential outcomes. However, its application in pediatric vascular access has not been comprehensively evaluated.AimWe developed an AR ultrasound application, HoloUS, using the Microsoft HoloLens 2 to display live ultrasound images directly in the proceduralist’s field of view. We presented our evaluation of the effect of using the Microsoft HoloLens 2 for point-of-care ultrasound (POCUS)-guided vascular access in 30 pediatric patients.ApproachA custom software module was developed on a tablet capable of capturing the moving ultrasound image from any ultrasound machine’s screen. The captured image was compressed and sent to the HoloLens 2 via a hotspot without needing Internet access. On the HoloLens 2, we developed a custom software module to receive, decompress, and display the live ultrasound image. Hand gesture and voice command features were implemented for the user to reposition, resize, and change the gain and the contrast of the image. We evaluated 30 (15 successful control and 12 successful interventional) cases completed in a single-center, prospective, randomized study.ResultsThe mean overall rendering latency and the rendering frame rate of the HoloUS application were 139.30 ms (σ=32.02 ms) and 30 frames per second, respectively. The average procedure completion time was 17.3% shorter using AR guidance. The numbers of puncture attempts and needle redirections were similar between the two groups, and the number of head adjustments was minimal in the interventional group.ConclusionWe presented our evaluation of the results from the first study using the Microsoft HoloLens 2 that investigates AR-based POCUS-guided vascular access in pediatric patients. Our evaluation confirmed clinical feasibility and potential improvement in procedural efficiency.Keywords
This publication has 20 references indexed in Scilit:
- Color Rendering in Medical Extended-Reality ApplicationsJournal of Digital Imaging, 2020
- Selection and Insertion of Vascular Access Devices in Pediatrics: A Systematic ReviewPediatrics, 2020
- Managing complexity in the operating room: a group interview studyBMC Health Services Research, 2020
- Incidence and Classification of Nonroutine Events during Anesthesia CareAnesthesiology, 2020
- Evaluation of HoloLens Tracking and Depth Sensing for Indoor Mapping ApplicationsSensors, 2020
- The Interaction Between Text Modality and the Learner’s Modality Preference Influences Comprehension and Cognitive LoadFrontiers in Psychology, 2020
- Use of smart glasses for ultrasound-guided peripheral venous access: a randomized controlled pilot studyClinical and Experimental Emergency Medicine, 2019
- Vascular access in childrenIndian Journal of Anaesthesia, 2019
- Ultrasound-Guided Central Venous Access Using Google GlassThe Journal of Emergency Medicine, 2014
- Guidelines for Performing Ultrasound Guided Vascular Cannulation: Recommendations of the American Society of Echocardiography and the Society of Cardiovascular AnesthesiologistsJournal of the American Society of Echocardiography, 2011