Super-Resolution Ultrasound Imaging Using the Erythrocytes—Part I: Density Images
Authors:
- Jørgen Arendt JensenJJJørgen Arendt Jensen
- Mostafa Amin NajiMNMostafa Amin Naji
- Sebastian Kazmarek PræsiusSPSebastian Kazmarek Præsius
- Mikkel SchouMSMikkel Schou
- Lauge Naur HansenLHLauge Naur Hansen
- Stinne Byrholdt SøgaardSSStinne Byrholdt Søgaard
- Nathalie Sarup PanduroNPNathalie Sarup Panduro
- Charlotte Mehlin SørensenCSCharlotte Mehlin Sørensen
- Michael Bachmann NielsenMichael Bachmann Nielsen
Open Access
- 10 June 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 925-944
Abstract
A new approach for vascular super resolution imaging using the erythrocytes as targets (SURE imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index for ultrasound scanning for an increased penetration depth. A synthetic aperture ultrasound sequence was employed with 12 virtual sources using a 10 MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was 1.20λ,(185.0μm) and the lateral resolution was 1.50λ,(231.3μm). Field IIpro simulations were conducted on 12.5 μm radius vessel pairs with varying separations. A vessel pair with a separation of 70 μm could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging, and for 46.8 s for super resolution (SR) imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-CT contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6 μm voxel size for 11 hours, and for 20 hours in a 5 μm voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 μm, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 to 10 s. The vessel structure in the cortex was also similar for the SURE and SR images. Fourier ring correlation indicated a resolution capability of 29 μm. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.Keywords
Funding Information
- European Research Council’s Synergy (854796)
This publication has 57 references indexed in Scilit:
- Ultrasound super-resolution imaging with a hierarchical Kalman trackerUltrasonics, 2022
- 3D printed calibration micro-phantoms for super-resolution ultrasound imaging validationUltrasonics, 2021
- Subwavelength motion-correction for ultrafast ultrasound localization microscopyUltrasonics, 2017
- RECIST 1.1—Update and clarification: From the RECIST committeeEuropean Journal of Cancer, 2016
- Micro-CT Imaging of Tumor AngiogenesisThe American Journal of Pathology, 2014
- Fourier ring correlation as a resolution criterion for super-resolution microscopyJournal of Structural Biology, 2013
- Synthetic aperture ultrasound imagingUltrasonics, 2006
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- Fourier shell correlation threshold criteriaJournal of Structural Biology, 2005
- Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic powerUltrasound in Medicine & Biology, 2005