Chlamydia antibody testing in screening for tubal factor subfertility: the significance of IgG antibody decline over time
Authors:
Open Access
- 1 March 2002
- journal article
- research article
- Published by Oxford University Press (OUP) in Human Reproduction
- Vol. 17 (3) , 699-703
Abstract
BACKGROUND: Chlamydia (C.) trachomatis antibody testing in screening for tubal factor subfertility is limited by false negative results, i.e. negative Chlamydia antibody tests in patients with tubal pathology at laparoscopy. The present study was performed to determine whether decline in C. trachomatis IgG antibodies over time is responsible for those false negative results. METHODS: A total of 39 women with an initial titre of ≥64 were re-studied after 4–7 years. A new serum sample was collected from each patient. The initial and the second serum sample were tested for C. trachomatis IgG antibodies using a micro-immunofluorescence assay (MIF). A species-specific enzyme-linked immunosorbent assay (ELISA) was used to validate the MIF test results. All patients filled out a questionnaire to determine risk factors for renewed C. trachomatis infection between the initial and second serum sample. RESULTS: Seven of the 39 patients (18.0%) showed a decline (>2 titre steps) in IgG antibodies by MIF over a period of 4–7 years, but IgG antibodies never became undetectable. In the 7/39 patients who showed a decline by MIF, signal/cut-off values by ELISA did not change. CONCLUSION: A decline in IgG antibody titre is not a significant cause of false negative Chlamydia antibody test results.Keywords
This publication has 14 references indexed in Scilit:
- Chlamydia pneumoniae and screening for tubal factor subfertilityHuman Reproduction, 2001
- Screening for Chlamydia trachomatis in subfertile womenHuman Reproduction, 1999
- How to use Chlamydia antibody testing in subfertility patientsHuman Reproduction, 1998
- Chlamydial serology in 1303 asymptomatic subfertile couplesHuman Reproduction, 1997
- The accuracy of serum chlamydial antibodies in the diagnosis of tubal pathology: a meta-analysisFertility and Sterility, 1997
- Post-therapeutic evolution of serum chlamydial antibody titers in women with acute salpingitis and tubal infertilityFertility and Sterility, 1994
- Antibodies to Chlamydia Species in Patients Attending a Genitourinary Clinic and the Impact of Antibodies to C. pneumoniae and C. psittaci on the Sensitivity and the Specificity of C. trachomatis Serology TestsSexually Transmitted Diseases, 1993
- Persistence of antichlamydial antibodies after treatment of acute salpingitis with doxycyclineEuropean Journal of Obstetrics & Gynecology and Reproductive Biology, 1993
- The long term follow-up of asymptomatic women with Chlamydia trachomatisArchives of Gynecology and Obstetrics, 1992
- Serological diagnosis with the Chlamydia Spot-IF testJournal of Medical Microbiology, 1991