Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey
Authors:
- Ernest U EkpoEEErnest U Ekpo
- Owujekwe C EmekaOEOwujekwe C Emeka
- 13 March 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (2) , 525-535
Abstract
Purpose . To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. Materials and Methods . This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDI vol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E DLP = k × DLP ). Results . The proposed 75th percentile CTDI vol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Conclusion . Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDI vol comparable to international standards, but considerably higher DLP and effective doses.Keywords
This publication has 32 references indexed in Scilit:
- Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical auditEuropean Radiology, 2013
- Radiation exposure among patients with the highest CT scan utilization in the emergency departmentEmergency Radiology, 2013
- Establishment of CT diagnostic reference levels in IrelandBritish Journal of Radiology, 2012
- Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasetsJournal of Cardiovascular Computed Tomography, 2012
- Diagnostic reference level of computed tomography (CT) in japanRadiation Protection Dosimetry, 2011
- Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levelsRadiation Protection Dosimetry, 2010
- Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction AlgorithmAmerican Journal of Roentgenology, 2010
- Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of CancerArchives of internal medicine (1960), 2009
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Variations in radiation dose between the same model of multislice CT scanner at different hospitalsBritish Journal of Radiology, 2003