Detection of creatinine using silver nanoparticles on a poly(pyrrole) thin film-based surface plasmon resonance sensor
Authors:
- Chammari PothiporCPChammari Pothipor
- Chutiparn LertvachirapaiboonCLChutiparn Lertvachirapaiboon
- Kazunari ShinboKSKazunari Shinbo
- Keizo KatoKKKeizo Kato
- Kontad OunnunkadKOKontad Ounnunkad
- Akira BabaABAkira Baba
- 28 November 2019
- journal article
- conference paper
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SC) , SCCA02
Abstract
Surface plasmon resonance (SPR) technique is a great tool to investigate the binding of analyte to functionalized surfaces and the immobilization of biomolecules. Creatinine is one of the biomarkers for monitoring renal functions and making a diagnosis of kidney disease. Elevated creatinine levels in the human body signifies impaired kidney disease. In this work, we developed a new strategy for creatinine detection using starch stabilized silver nanoparticles (starch-AgNPs) on poly(pyrrole) (PPy) thin film using the SPR technique. The assay exhibited the obvious change from yellow to orange color of AgNPs solution in the presence of creatinine, showing good sensitivity due to the localized plasmon effect of AgNPs. Based on this effect, the change of SPR reflectivity in the Kretschmann configuration was enhanced by the adsorption of AgNPs in the presence of creatinine on the PPy film. The SPR reflectivity upon the injection of the mixed solution on the PPy thin film increased with increasing creatinine concentration in the linear range from 10 to 1000 μ M. As a comparison, performances of the creatinine sensor with three SPR sensor systems, i.e. only PPy film, PPy film with AgNPs, and PPy film with aggregated AgNPs, were studied. The SPR sensor with aggregated AgNPs was improved approximately four times compared with the substrate without aggregated AgNPs, and the limit of the detection was 0.19 μ M. The proposed method is potentially useful for clinical applications.Keywords
This publication has 34 references indexed in Scilit:
- An improved electrochemical creatinine detection method via a Jaffe-based procedureThe Analyst, 2013
- LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers’ 24 Hour UrineJournal of Analytical Methods in Chemistry, 2012
- Serum Creatinine Detection by a Conducting-Polymer-Based Electrochemical Sensor To Identify Allograft DysfunctionAnalytical Chemistry, 2012
- Functional Conducting Polymers in the Application of SPR BiosensorsJournal of Nanotechnology, 2012
- Surface plasmon resonance imaging detection of silver nanoparticle-tagged immunoglobulinJournal of The Royal Society Interface, 2011
- Detection of Human IgG on Poly(pyrrole-3-carboxylic acid) Thin Film by Electrochemical-Surface Plasmon Resonance SpectroscopyJapanese Journal of Applied Physics, 2011
- Electrochemical Surface Plasmon Resonance and Waveguide-Enhanced Glucose Biosensing with N-Alkylaminated Polypyrrole/Glucose Oxidase MultilayersACS Applied Materials & Interfaces, 2010
- Applications of conducting polymers and their issues in biomedical engineeringJournal of The Royal Society Interface, 2010
- Electrochemically controlled surface plasmon resonance immunosensor for the detection of human immunoglobulin G on poly(3-aminobenzoic acid) ultrathin filmsSensors and Actuators B: Chemical, 2010
- Very fast and direct capillary zone electrophoresis method for the determination of creatinine and creatine in human urineAnalytica Chimica Acta, 2004