Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion
Open Access
- 15 September 2015
- Vol. 15 (9) , 23168-23187
Abstract
Over the years, smartphones have become tools for scientific and clinical research. They can, for instance, be used to assess range of motion and joint angle measurement. In this paper, our aim was to determine if smartphones are reliable and accurate enough for clinical motion research. This work proposes an evaluation of different smartphone sensors performance and different manufacturer algorithm performances with the comparison to the gold standard, an industrial robotic arm with an actual standard use inertial motion unit in clinical measurement, an Xsens product. Both dynamic and static protocols were used to perform these comparisons. Root Mean Square (RMS) mean values results for static protocol are under 0.3° for the different smartphones. RMS mean values results for dynamic protocol are more prone to bias induced by Euler angle representation. Statistical results prove that there are no filter effect on results for both protocols and no hardware effect. Smartphones performance can be compared to the Xsens gold standard for clinical research.Keywords
This publication has 24 references indexed in Scilit:
- Definition dependent properties of the cortical silent period in upper-extremity muscles, a methodological studyJournal of NeuroEngineering and Rehabilitation, 2014
- Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of VelocityPLOS ONE, 2013
- Measurement of the Knee Flexion Angle With a Smartphone-Application is Precise and AccurateThe Journal of Arthroplasty, 2013
- A smartphone-based fall detection systemPervasive and Mobile Computing, 2012
- Evaluation of a visual feedback system in gait retraining: A pilot studyGait & Posture, 2012
- Pervasive computing at scale: Transforming the state of the artPervasive and Mobile Computing, 2012
- Validity of VICON Motion Analysis System for Upper Limb Kinematic MeasuremeNT – A Comparison Study with Inertial Tracking Xsens SystemHong Kong Physiotherapy Journal, 2011
- Feasibility of using inertial sensors to assess human movementManual Therapy, 2010
- Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensorsMedical & Biological Engineering & Computing, 2007
- Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjectsPhysiotherapy Research International, 1997