CT attenuation correction improves quantitative risk prediction by cardiac SPECT in obese patients
Authors:
- 4 November 2023
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 51 (3) , 695-706
Abstract
Purpose This study aimed to compare the predictive value of CT attenuation-corrected stress total perfusion deficit (AC-sTPD) and non-corrected stress TPD (NC-sTPD) for major adverse cardiac events (MACE) in obese patients undergoing cadmium zinc telluride (CZT) SPECT myocardial perfusion imaging (MPI). Methods The study included 4,585 patients who underwent CZT SPECT/CT MPI for clinical indications (chest pain: 56%, shortness of breath: 13%, other: 32%) at Yale New Haven Hospital (age: 64 ± 12 years, 45% female, body mass index [BMI]: 30.0 ± 6.3 kg/m2, prior coronary artery disease: 18%). The association between AC-sTPD or NC-sTPD and MACE defined as the composite end point of mortality, nonfatal myocardial infarction or late coronary revascularization (> 90 days after SPECT) was evaluated with survival analysis. Results During a median follow-up of 25 months, 453 patients (10%) experienced MACE. In patients with BMI ≥ 35 kg/m2 (n = 931), those with AC-sTPD ≥ 3% had worse MACE-free survival than those with AC-sTPD < 3% (HR: 2.23, 95% CI: 1.40 – 3.55, p = 0.002) with no difference in MACE-free survival between patients with NC-sTPD ≥ 3% and NC-sTPD < 3% (HR:1.06, 95% CI:0.67 – 1.68, p = 0.78). AC-sTPD had higher AUC than NC-sTPD for the detection of 2-year MACE in patients with BMI ≥ 35 kg/m2 (0.631 versus 0.541, p = 0.01). In the overall cohort AC-sTPD had a higher ROC area under the curve (AUC, 0.641) than NC-sTPD (0.608; P = 0.01) for detection of 2-year MACE. In patients with BMI ≥ 35 kg/m2 AC sTPD provided significant incremental prognostic value beyond NC sTPD (net reclassification index: 0.14 [95% CI: 0.20 – 0.28]). Conclusions AC sTPD outperformed NC sTPD in predicting MACE in patients undergoing SPECT MPI with BMI ≥ 35 kg/m2. These findings highlight the superior prognostic value of AC-sTPD in this patient population and underscore the importance of CT attenuation correction.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL089765, R35HL161195)
This publication has 33 references indexed in Scilit:
- Exercise Standards for Testing and TrainingCirculation, 2013
- SPECT myocardial perfusion imaging as an adjunct to coronary calcium score for the detection of hemodynamically significant coronary artery stenosisBMC Cardiovascular Disorders, 2012
- Improved Outcome Prediction by SPECT Myocardial Perfusion Imaging After CT Attenuation CorrectionJournal of Nuclear Medicine, 2011
- Extensions of net reclassification improvement calculations to measure usefulness of new biomarkersStatistics in Medicine, 2010
- Quantitative Upright–Supine High-Speed SPECT Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: Correlation with Invasive Coronary AngiographyJournal of Nuclear Medicine, 2010
- Combined quantitative analysis of attenuation corrected and non-corrected myocadial perfusion SPECT: Method development and clinical validationJournal of Nuclear Cardiology, 2010
- The Coronary Artery Calcium Score and Stress Myocardial Perfusion Imaging Provide Independent and Complementary Prediction of Cardiac RiskJACC, 2009
- Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysisJournal of Nuclear Cardiology, 2009
- Impact of Body Mass Index on Cardiac Mortality in Patients With Known or Suspected Coronary Artery Disease Undergoing Myocardial Perfusion Single-Photon Emission Computed TomographyJACC, 2006
- Value of Stress Myocardial Perfusion Single Photon Emission Computed Tomography in Patients With Normal Resting ElectrocardiogramsCirculation, 2002